Fachartikel in der Zeitschrift Sensors, online erschienen am 24.05.2024. Verfasst von Mariam Ibrahim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechatronics Engineering, German Jordanian University, Amman 11180, Jordan. Hauptthemen laut MEDLINE: Computer Security, Internet of Things, Algorithms, Delivery of Health Care. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Deanship of Graduate Studies and Scientific Research at the German Jordanian University, Deanship of Graduate Studies and Scientific Research at the German Jordanian University.
Abstract (Originalsprache)
The healthcare industry went through reformation by integrating the Internet of Medical Things (IoMT) to enable data harnessing by transmission mediums from different devices, about patients to healthcare staff devices, for further analysis through cloud-based servers for proper diagnosis of patients, yielding efficient and accurate results. However, IoMT technology is accompanied by a set of drawbacks in terms of security risks and vulnerabilities, such as violating and exposing patients’ sensitive and confidential data. Further, the network traffic data is prone to interception attacks caused by a wireless type of communication and alteration of data, which could cause unwanted outcomes. The advocated scheme provides insight into a robust Intrusion Detection System (IDS) for IoMT networks. It leverages a honeypot to divert attackers away from critical systems, reducing the attack surface. Additionally, the IDS employs an ensemble method combining Logistic Regression and K-Nearest Neighbor algorithms. This approach harnesses the strengths of both algorithms to improve attack detection accuracy and robustness. This work analyzes the impact, performance, accuracy, and precision outcomes of the used model on two IoMT-related datasets which contain multiple attack types such as Man-In-The-Middle (MITM), Data Injection, and Distributed Denial of Services (DDOS). The yielded results showed that the proposed ensemble method was effective in detecting intrusion attempts and classifying them as attacks or normal network traffic, with a high accuracy of 92.5% for the first dataset and 99.54% for the second dataset and a precision of 96.74% for the first dataset and 99.228% for the second dataset.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechatronics Engineering, German Jordanian University, Amman 11180, Jordan.
ORCID-Profile: Mariam Ibrahim
Förderung
- the Deanship of Graduate Studies and Scientific Research at the German Jordanian University
- Deanship of Graduate Studies and Scientific Research at the German Jordanian University
Zitieren
APA
Ibrahim, M., Al-Wadi, A., & Elhafiz, R. (2024). Security Analysis for Smart Healthcare Systems. Sensors, 24(11), 3375. https://doi.org/10.3390/s24113375
Vancouver
Ibrahim M, Al-Wadi A, Elhafiz R. Security Analysis for Smart Healthcare Systems. Sensors. 2024;24(11):3375. doi:10.3390/s24113375
BibTeX
@article{Ibrahim2024,
author = {Ibrahim, Mariam and Al-Wadi, Abdallah and Elhafiz, Ruba},
title = {Security Analysis for Smart Healthcare Systems},
journal = {Sensors},
year = {2024},
volume = {24},
number = {11},
pages = {3375},
doi = {10.3390/s24113375}
}
EUVIMED