Direct Measurement of Dissolved Gas Using a Tapered Single-Mode Silica Fiber
Sensors · 17.05.2024 · 24 (10) · 3200
DOI: 10.3390/s24103200 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 17.05.2024. Verfasst von Panpan Sun und 7 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Advanced Manufacturing for Optical Systems (CAS), Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sci…. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jilin Provincial Natural Science Foundation, National Natural Science Foundation of China, National Key Research and Development Program of China.
Abstract (Originalsprache)
Dissolved gases in the aquatic environment are critical to understanding the population of aquatic organisms and the ocean. Currently, laser absorption techniques based on membrane separation technology have made great strides in dissolved gas detection. However, the prolonged water–gas separation time of permeable membranes remains a key obstacle to the efficiency of dissolved gas analysis. To mitigate these limitations, we demonstrated direct measurement of dissolved gas using the evanescent-wave absorption spectroscopy of a tapered silica micro-fiber. It enhanced the analysis efficiency of dissolved gases without water–gas separation or sample preparation. The feasibility of this sensor for direct measurement of dissolved gases was verified by taking the detection of dissolved ammonia as an example. With a sensing length of 5 mm and a consumption of ~50 µL, this sensor achieves a system response time of ~11 min and a minimum detection limit (MDL) of 0.015%. Possible strategies are discussed for further performance improvement in in-situ applications requiring fast and highly sensitive dissolved gas sensing.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Laboratory of Advanced Manufacturing for Optical Systems (CAS), Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
- University of Chinese Academy of Sciences, Beijing 100049, China.
- State Key Laboratory of Luminescence Science and Technology (SKLST), Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
ORCID-Profile: Jinguang Lv, Qiang Wang
Förderung
- Jilin Provincial Natural Science Foundation
- National Natural Science Foundation of China
- National Key Research and Development Program of China
- the Second Comprehensive Scientific Investigation of the Qinghai-Tibet Plateau
- the Young Talent of Lifting Engineering for Science and Technology in Jilin, China
- Second Comprehensive Scientific Investigation of the Qinghai-Tibet Plateau
- Young Talent of Lifting Engineering for Science and Technology in Jilin
- Science and Technology Development Project of Jilin Province
Zitieren
APA
Sun, P., Hu, M., Zhu, L., Zhang, H., Lv, J., Liu, Y., Liang, J., & Wang, Q. (2024). Direct Measurement of Dissolved Gas Using a Tapered Single-Mode Silica Fiber. Sensors, 24(10), 3200. https://doi.org/10.3390/s24103200
Vancouver
Sun P, Hu M, Zhu L, Zhang H, Lv J, Liu Y, et al. Direct Measurement of Dissolved Gas Using a Tapered Single-Mode Silica Fiber. Sensors. 2024;24(10):3200. doi:10.3390/s24103200
BibTeX
@article{Sun2024,
author = {Sun, Panpan and Hu, Mengpeng and Zhu, Licai and Zhang, Hui and Lv, Jinguang and Liu, Yu and Liang, Jingqiu and Wang, Qiang},
title = {Direct Measurement of Dissolved Gas Using a Tapered Single-Mode Silica Fiber},
journal = {Sensors},
year = {2024},
volume = {24},
number = {10},
pages = {3200},
doi = {10.3390/s24103200}
}
EUVIMED