High-Frequency and High-Current Transmission Techniques for Multiple Earth Electrical Characteristic Measurement Systems Based on Adaptive Impedance Matching through Phase Comparison
Sensors · 14.05.2024 · 24 (10) · 3110
DOI: 10.3390/s24103110 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 14.05.2024. Verfasst von Kuiyuan Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Geophysics and Information Technology, China University of Geosciences Beijing, Beijing 100083, China. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Program Project, National Natural Science Foundation of China, MOST Special Fund from the State Key Laboratory of Geological Processes and Mineral Resources.
Abstract (Originalsprache)
With the increase in groundwater exploration, underground mineral resource exploration, and non-destructive investigation of cultural relics, high-resolution earth electrical characteristic measurement has emerged as a mainstream technique owing to its advantageous non-destructive detection capability. To enhance the transmission power of the high-frequency transmitter in high-resolution multiple earth electrical characteristic measurement systems (MECS), this study proposes a high-frequency, high-current transmission technique based on adaptive impedance matching and implemented through the integration of resonant capacitors, a controllable reactor, high-frequency transformers, and corresponding control circuits. A high-current precisely controllable reactor with a 94% inductance variation range was designed and combined with resonant capacitors to reduce circuit impedance. Additionally, high-frequency transformers were employed to further increase the transmission voltage. A prototype was developed and tested, demonstrating an increase in transmission current at frequencies between 10 and 120 kHz with a peak active power of 200 W. Under the same transmission voltage, compared to the transmission circuit without impedance matching, the transmission current increased to a maximum of 16.7 times (average of 10.8 times), whereas compared to the transmission circuit using only traditional impedance matching, the transmission current increased by a maximum of 10.0 times (average of 4.2 times), effectively improving the exploration resolution.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Geophysics and Information Technology, China University of Geosciences Beijing, Beijing 100083, China.
- Key Laboratory of Intraplate Volcanoes and Earthquakes, China University of Geosciences, Beijing 100083, China.
- State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Beijing 100083, China.
ORCID-Profile: Meng Wang
Förderung
- National Key R&D Program Project
- National Natural Science Foundation of China
- MOST Special Fund from the State Key Laboratory of Geological Processes and Mineral Resources
- National Key R&D Program Project
Zitieren
APA
Zhang, K., Yang, S., Wang, M., & Zhang, R. (2024). High-Frequency and High-Current Transmission Techniques for Multiple Earth Electrical Characteristic Measurement Systems Based on Adaptive Impedance Matching through Phase Comparison. Sensors, 24(10), 3110. https://doi.org/10.3390/s24103110
Vancouver
Zhang K, Yang S, Wang M, Zhang R. High-Frequency and High-Current Transmission Techniques for Multiple Earth Electrical Characteristic Measurement Systems Based on Adaptive Impedance Matching through Phase Comparison. Sensors. 2024;24(10):3110. doi:10.3390/s24103110
BibTeX
@article{Zhang2024,
author = {Zhang, Kuiyuan and Yang, Shulin and Wang, Meng and Zhang, Rongbo},
title = {High-Frequency and High-Current Transmission Techniques for Multiple Earth Electrical Characteristic Measurement Systems Based on Adaptive Impedance Matching through Phase Comparison},
journal = {Sensors},
year = {2024},
volume = {24},
number = {10},
pages = {3110},
doi = {10.3390/s24103110}
}
EUVIMED