Enhancing Fetal Electrocardiogram Signal Extraction Accuracy through a CycleGAN Utilizing Combined CNN–BiLSTM Architecture
Sensors · 06.05.2024 · 24 (9) · 2948
DOI: 10.3390/s24092948 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 06.05.2024. Verfasst von Yuyao Yang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, College of Chemistry and Life Science, Beijing University of Technology, Beijing 100124, China. Hauptthemen laut MEDLINE: Electrocardiography, Neural Networks, Computer, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Beijing Natural Science Foundation.
Abstract (Originalsprache)
The fetal electrocardiogram (FECG) records changes in the graph of fetal cardiac action potential during conduction, reflecting the developmental status of the fetus in utero and its physiological cardiac activity. Morphological alterations in the FECG can indicate intrauterine hypoxia, fetal distress, and neonatal asphyxia early on, enhancing maternal and fetal safety through prompt clinical intervention, thereby reducing neonatal morbidity and mortality. To reconstruct FECG signals with clear morphological information, this paper proposes a novel deep learning model, CBLS-CycleGAN. The model’s generator combines spatial features extracted by the CNN with temporal features extracted by the BiLSTM network, thus ensuring that the reconstructed signals possess combined features with spatial and temporal dependencies. The model’s discriminator utilizes PatchGAN, employing small segments of the signal as discriminative inputs to concentrate the training process on capturing signal details. Evaluating the model using two real FECG signal databases, namely “Abdominal and Direct Fetal ECG Database” and “Fetal Electrocardiograms, Direct and Abdominal with Reference Heartbeat Annotations”, resulted in a mean MSE and MAE of 0.019 and 0.006, respectively. It detects the FQRS compound wave with a sensitivity, positive predictive value, and F1 of 99.51%, 99.57%, and 99.54%, respectively. This paper’s model effectively preserves the morphological information of FECG signals, capturing not only the FQRS compound wave but also the fetal P-wave, T-wave, P-R interval, and ST segment information, providing clinicians with crucial diagnostic insights and a scientific foundation for developing rational treatment protocols.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, College of Chemistry and Life Science, Beijing University of Technology, Beijing 100124, China.
Förderung
- National Natural Science Foundation of China
- Beijing Natural Science Foundation
Zitieren
APA
Yang, Y., Chen, L., & Wu, S. (2024). Enhancing Fetal Electrocardiogram Signal Extraction Accuracy through a CycleGAN Utilizing Combined CNN–BiLSTM Architecture. Sensors, 24(9), 2948. https://doi.org/10.3390/s24092948
Vancouver
Yang Y, Chen L, Wu S. Enhancing Fetal Electrocardiogram Signal Extraction Accuracy through a CycleGAN Utilizing Combined CNN–BiLSTM Architecture. Sensors. 2024;24(9):2948. doi:10.3390/s24092948
BibTeX
@article{Yang2024,
author = {Yang, Yuyao and Chen, Lin and Wu, Shuicai},
title = {Enhancing Fetal Electrocardiogram Signal Extraction Accuracy through a CycleGAN Utilizing Combined CNN–BiLSTM Architecture},
journal = {Sensors},
year = {2024},
volume = {24},
number = {9},
pages = {2948},
doi = {10.3390/s24092948}
}
EUVIMED