Development and Evaluation of a Hybrid Measurement System to Determine the Kinematics of the Wrist

Jason Dellai, Martine A Gilles, Olivier Remy, Laurent Claudon, Gilles Dietrich

Sensors · 2024

DOI: 10.3390/s24082543 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Jason Dellai und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institut National de Recherche et de Sécurité (INRS), 54519 Vandoeuvre-lès-Nancy, France. Hauptthemen laut MEDLINE: Wrist. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optical Motion Capture Systems (OMCSs) are considered the gold standard for kinematic measurement of human movements. However, in situations such as measuring wrist kinematics during a hairdressing activity, markers can be obscured, resulting in a loss of data. Other measurement methods based on non-optical data can be considered, such as magneto-inertial measurement units (MIMUs). Their accuracy is generally lower than that of an OMCS. In this context, it may be worth considering a hybrid system [MIMU + OMCS] to take advantage of OMCS accuracy while limiting occultation problems. The aim of this work was (1) to propose a methodology for coupling a low-cost MIMU (BNO055) to an OMCS in order to evaluate wrist kinematics, and then (2) to evaluate the accuracy of this hybrid system [MIMU + OMCS] during a simple hairdressing gesture. During hair cutting gestures, the root mean square error compared with the OMCS was 4.53° (1.45°) for flexion/extension, 5.07° (1.30°) for adduction/abduction, and 3.65° (1.19°) for pronation/supination. During combing gestures, they were significantly higher, but remained below 10°. In conclusion, this system allows for maintaining wrist kinematics in case of the loss of hand markers while preserving an acceptable level of precision (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WristHumansBiomechanical PhenomenaMaleRange of Motion, ArticularAdultMovementFemale

Stichwörter der Autor:innen

MIMUaccuracyhybrid systemoptical motion capture systemwrist kinematic

Autor:innen und Institutionen

  • Institut National de Recherche et de Sécurité (INRS), 54519 Vandoeuvre-lès-Nancy, France.
  • Institut des Sciences du Sport Santé de Paris (URP 3625), Université Paris Cité, 75015 Paris, France.

Zitieren

APA

Dellai, J., Gilles, M. A., Remy, O., Claudon, L., & Dietrich, G. (2024). Development and Evaluation of a Hybrid Measurement System to Determine the Kinematics of the Wrist. Sensors. https://doi.org/10.3390/s24082543

Vancouver

Dellai J, Gilles MA, Remy O, Claudon L, Dietrich G. Development and Evaluation of a Hybrid Measurement System to Determine the Kinematics of the Wrist. Sensors. 2024. doi:10.3390/s24082543

BibTeX
@article{Dellai2024,
  author = {Dellai, Jason and Gilles, Martine A and Remy, Olivier and Claudon, Laurent and Dietrich, Gilles},
  title = {Development and Evaluation of a Hybrid Measurement System to Determine the Kinematics of the Wrist},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24082543}
}