Potentiometric Surfactant Sensor with a Pt-Doped Acid-Activated Multi-Walled Carbon Nanotube-Based Ionophore Nanocomposite
Sensors · 09.04.2024 · 24 (8) · 2388
DOI: 10.3390/s24082388 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 09.04.2024. Verfasst von Nada Glumac und 9 weiteren Autor:innen. Beteiligte Einrichtung: Međimurske Vode D.O.O., 40000 Čakovec, Croatia. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science, Technological Development and Innovations of the Republic of Serbia.
Abstract (Originalsprache)
Two new surfactant sensors were developed by synthesizing Pt-doped acid-activated multi-walled carbon nanotubes (Pt@MWCNTs). Two different ionophores using Pt@MWCNTs, a new plasticizer, and (a) cationic surfactant 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-DHBI (Pt@MWCNT-DHBI ionophore) and (b) anionic surfactant dodecylbenzenesulfonate-DBS (Pt@MWCNT-DBS ionophore) composites were successfully synthesized and characterized. Both surfactant sensors showed a response to anionic surfactants (dodecylsulfate (SDS) and DBS) and cationic surfactants (cetylpyridinium chloride (CPC) and hexadecyltrimethylammonium bromide (CTAB)). The Pt@MWCNT-DBS sensor showed lower sensitivity than expected with the sub-Nernstian response of ≈23 mV/decade of activity for CPC and CTAB and ≈33 mV/decade of activity for SDS and DBS. The Pt@MWCNT-DHBI surfactant sensor had superior response properties, including a Nernstian response to SDS (59.1 mV/decade) and a near-Nernstian response to DBS (57.5 mV/decade), with linear response regions for both anionic surfactants down to ≈2 × 10−6 M. The Pt@MWCNT-DHBI was also useful in critical micellar concentration (CMC) detection. Common anions showed very low interferences with the sensor. The sensor was successfully employed for the potentiometric titration of a technical grade cationic surfactant with good recoveries. The content of cationic surfactants was measured in six samples of complex commercial detergents. The Pt@MWCNT-DHBI surfactant sensor showed good agreement with the ISE surfactant sensor and classical two-phase titration and could be used as an analytical tool in quality control.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Međimurske Vode D.O.O., 40000 Čakovec, Croatia.
- Faculty of Sciences and Mathematics, University of Niš, 18000 Niš, Serbia.
- Faculty of Electrical Engineering and Computer Science, University of Maribor, 2000 Maribor, Slovenia.
- Faculty of Geotechnical Engineering, University of Zagreb, 42000 Varaždin, Croatia.
- Department of Chemistry, University of Osijek, 31000 Osijek, Croatia.
- Department of Civil Engineering, University North, 42000 Varaždin, Croatia.
ORCID-Profile: Iztok Kramberger, Elvira Kovač-Andrić, Bojan Đurin, Kristina Đambić, Marija Jozanović
Förderung
- Ministry of Science, Technological Development and Innovations of the Republic of Serbia
Zitieren
APA
Glumac, N., Momčilović, M., Kramberger, I., Štraus, D., Sakač, N., Kovač-Andrić, E., Đurin, B., Kraševac Sakač, M., Đambić, K., & Jozanović, M. (2024). Potentiometric Surfactant Sensor with a Pt-Doped Acid-Activated Multi-Walled Carbon Nanotube-Based Ionophore Nanocomposite. Sensors, 24(8), 2388. https://doi.org/10.3390/s24082388
Vancouver
Glumac N, Momčilović M, Kramberger I, Štraus D, Sakač N, Kovač-Andrić E, et al. Potentiometric Surfactant Sensor with a Pt-Doped Acid-Activated Multi-Walled Carbon Nanotube-Based Ionophore Nanocomposite. Sensors. 2024;24(8):2388. doi:10.3390/s24082388
BibTeX
@article{Glumac2024,
author = {Glumac, Nada and Momčilović, Milan and Kramberger, Iztok and Štraus, Darko and Sakač, Nikola and Kovač-Andrić, Elvira and Đurin, Bojan and Kraševac Sakač, Marija and Đambić, Kristina and Jozanović, Marija},
title = {Potentiometric Surfactant Sensor with a Pt-Doped Acid-Activated Multi-Walled Carbon Nanotube-Based Ionophore Nanocomposite},
journal = {Sensors},
year = {2024},
volume = {24},
number = {8},
pages = {2388},
doi = {10.3390/s24082388}
}