EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Response of the TEROS 12 Soil Moisture Sensor under Different Soils and Variable Electrical Conductivity

Athanasios Fragkos iD, Dimitrios Loukatos iD, Georgios Kargas iD, Konstantinos G Arvanitis iD

Sensors · 29.03.2024 · 24 (7) · 2206

DOI: 10.3390/s24072206 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 29.03.2024. Verfasst von Athanasios Fragkos und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Natural Resources Management and Agricultural Engineering, Agricultural University of Athens, 75 Iera Odos Str., 11855 Athens, Greece. Die Arbeit wurde bisher 39-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this work, the performance of the TEROS 12 electromagnetic sensor, which measures volumetric soil water content (θ), bulk soil electrical conductivity (σb), and temperature, is examined for a number of different soils, different θ and different levels of the electrical conductivity of the soil solution (ECW) under laboratory conditions. For the above reason, a prototype device was developed including a low-cost microcontroller and suitable adaptation circuits for the aforementioned sensor. Six characteristic porous media were examined in a θ range from air drying to saturation, while four different solutions of increasing Electrical Conductivity (ECw) from 0.28 dS/m to approximately 10 dS/m were used in four of these porous media. It was found that TEROS 12 apparent dielectric permittivity (εa) readings were lower than that of Topp’s permittivity–water content relationship, especially at higher soil water content values in the coarse porous bodies. The differences are observed in sand (S), sandy loam (SL) and loam (L), at this order. The results suggested that the relationship between experimentally measured soil water content (θm) and εa0.5 was strongly linear (0.869 < R2 < 0.989), but the linearity of the relation θm-εa0.5 decreases with the increase in bulk EC (σb) of the soil. The most accurate results were provided by the multipoint calibration method (CAL), as evaluated with the root mean square error (RMSE). Also, it was found that εa degrades substantially at values of σb less than 2.5 dS/m while εa returns to near 80 at higher values. Regarding the relation εa-σb, it seems that it is strongly linear and that its slope depends on the pore water electrical conductivity (σp) and the soil type.

Schlagwörter

Stichwörter der Autor:innen

TEROS 12apparent dielectric permittivitycalibrationcrop productionelectrical conductivitymicrocontroller-based measurementsresource preservationsoil moisture

Autor:innen und Institutionen

  • Department of Natural Resources Management and Agricultural Engineering, Agricultural University of Athens, 75 Iera Odos Str., 11855 Athens, Greece.

ORCID-Profile: Athanasios Fragkos, Dimitrios Loukatos, Georgios Kargas, Konstantinos G Arvanitis

Zitieren

APA

Fragkos, A., Loukatos, D., Kargas, G., & Arvanitis, K. G. (2024). Response of the TEROS 12 Soil Moisture Sensor under Different Soils and Variable Electrical Conductivity. Sensors, 24(7), 2206. https://doi.org/10.3390/s24072206

Vancouver

Fragkos A, Loukatos D, Kargas G, Arvanitis KG. Response of the TEROS 12 Soil Moisture Sensor under Different Soils and Variable Electrical Conductivity. Sensors. 2024;24(7):2206. doi:10.3390/s24072206

BibTeX
@article{Fragkos2024,
  author = {Fragkos, Athanasios and Loukatos, Dimitrios and Kargas, Georgios and Arvanitis, Konstantinos G},
  title = {Response of the TEROS 12 Soil Moisture Sensor under Different Soils and Variable Electrical Conductivity},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {7},
  pages = {2206},
  doi = {10.3390/s24072206}
}