Online Calibration of Extrinsic Parameters for Solid-State LIDAR Systems
Sensors · 27.03.2024 · 24 (7) · 2155
DOI: 10.3390/s24072155 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 27.03.2024. Verfasst von Mark O Mints und 4 weiteren Autor:innen. Beteiligte Einrichtung: Active Vision Group, Institute for Computational Visualistics, University of Koblenz, 56016 Koblenz, Germany. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Office of Bundeswehr Equipment, Information Technology and In-Service Support, Open Access Fund of Universität Koblenz.
Abstract (Originalsprache)
This work addresses the challenge of calibrating multiple solid-state LIDAR systems. The study focuses on three different solid-state LIDAR sensors that implement different hardware designs, leading to distinct scanning patterns for each system. Consequently, detecting corresponding points between the point clouds generated by these LIDAR systems—as required for calibration—is a complex task. To overcome this challenge, this paper proposes a method that involves several steps. First, the measurement data are preprocessed to enhance its quality. Next, features are extracted from the acquired point clouds using the Fast Point Feature Histogram method, which categorizes important characteristics of the data. Finally, the extrinsic parameters are computed using the Fast Global Registration technique. The best set of parameters for the pipeline and the calibration success are evaluated using the normalized root mean square error. In a static real-world indoor scenario, a minimum root mean square error of 7 cm was achieved. Importantly, the paper demonstrates that the presented approach is suitable for online use, indicating its potential for real-time applications. By effectively calibrating the solid-state LIDAR systems and establishing point correspondences, this research contributes to the advancement of multi-LIDAR fusion and facilitates accurate perception and mapping in various fields such as autonomous driving, robotics, and environmental monitoring.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Active Vision Group, Institute for Computational Visualistics, University of Koblenz, 56016 Koblenz, Germany.
ORCID-Profile: Mark O Mints, Roman Abayev, Nick Theisen, Dietrich Paulus, Anselm von Gladiss
Förderung
- Federal Office of Bundeswehr Equipment, Information Technology and In-Service Support
- Open Access Fund of Universität Koblenz
Zitieren
APA
Mints, M. O., Abayev, R., Theisen, N., Paulus, D., & von Gladiss, A. (2024). Online Calibration of Extrinsic Parameters for Solid-State LIDAR Systems. Sensors, 24(7), 2155. https://doi.org/10.3390/s24072155
Vancouver
Mints MO, Abayev R, Theisen N, Paulus D, von Gladiss A. Online Calibration of Extrinsic Parameters for Solid-State LIDAR Systems. Sensors. 2024;24(7):2155. doi:10.3390/s24072155
BibTeX
@article{Mints2024,
author = {Mints, Mark O and Abayev, Roman and Theisen, Nick and Paulus, Dietrich and von Gladiss, Anselm},
title = {Online Calibration of Extrinsic Parameters for Solid-State LIDAR Systems},
journal = {Sensors},
year = {2024},
volume = {24},
number = {7},
pages = {2155},
doi = {10.3390/s24072155}
}