Sensor-Based Measurement Method to Support the Assessment of Robot-Assisted Radiofrequency Ablation
Sensors · 2024
DOI: 10.3390/s24051699 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Hilda Zsanett Marton und 4 weiteren Autor:innen. Beteiligte Einrichtung: Gottsegen National Cardiovascular Center, 1096 Budapest, Hungary. Hauptthemen laut MEDLINE: Robotics, Atrial Fibrillation, Radiofrequency Ablation, Catheter Ablation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research, Development and Innovation Fund of Hungary.
Abstract (Originalsprache)
Digital surgery technologies, such as interventional robotics and sensor systems, not only improve patient care but also aid in the development and optimization of traditional invasive treatments and methods. Atrial Fibrillation (AF) is the most common cardiac arrhythmia with critical clinical relevance today. Delayed intervention can lead to heart failure, stroke, or sudden cardiac death. Although many advances have been made in the field of radiofrequency (RF) catheter ablation (CA), it can be further developed by incorporating sensor technology to improve its efficacy and safety. Automation can be utilized to shorten the duration of RF ablation, provided that the interactions between the tissue and the RF tools are well understood and adequately modeled. Further research is needed to develop the optimal catheter design. This paper describes the systematic methodology developed to support robot-assisted RF CA characterization measurements. The article describes the custom instruments developed for the experiments, particularly the contact force limiter, the measurement procedure, and the evaluation of the results, as enablers for new results. The aim was to establish an objective, repeatable, robust measurement method and adjacent procedure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Gottsegen National Cardiovascular Center, 1096 Budapest, Hungary.
- Faculty of Medicine, Semmelweis University, 1085 Budapest, Hungary.
- Faculty of Mechanical Engineering, Budapest University of Technology and Economics, 1111 Budapest, Hungary.
- Austrian Center for Medical Innovation and Technology (ACMIT), 2700 Wiener Neustadt, Austria.
- University Research and Innovation Center (EKIK), Óbuda University, 1034 Budapest, Hungary.
ORCID-Profile: Hilda Zsanett Marton, Pálma Emese Inczeffy, Tamás Haidegger
Förderung
- National Research, Development and Innovation Fund of Hungary
Zitieren
APA
Marton, H. Z., Inczeffy, P. E., Kis, Z., Kardos, A., & Haidegger, T. (2024). Sensor-Based Measurement Method to Support the Assessment of Robot-Assisted Radiofrequency Ablation. Sensors. https://doi.org/10.3390/s24051699
Vancouver
Marton HZ, Inczeffy PE, Kis Z, Kardos A, Haidegger T. Sensor-Based Measurement Method to Support the Assessment of Robot-Assisted Radiofrequency Ablation. Sensors. 2024. doi:10.3390/s24051699
BibTeX
@article{Marton2024,
author = {Marton, Hilda Zsanett and Inczeffy, Pálma Emese and Kis, Zsuzsanna and Kardos, Attila and Haidegger, Tamás},
title = {Sensor-Based Measurement Method to Support the Assessment of Robot-Assisted Radiofrequency Ablation},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24051699}
}
EUVIMED