EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Comparative Study of Narrow/Ultra-Wideband Microwave Sensors for the Continuous Monitoring of Vital Signs and Lung Water Level

Anwer S Abd El-Hameed iD, Dalia M Elsheakh iD, Gomaa M Elashry, Esmat A Abdallah

Sensors · 2024

DOI: 10.3390/s24051658 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Anwer S Abd El-Hameed und 3 weiteren Autor:innen. Beteiligte Einrichtung: Microstrip Department, Electronics Research Institute (ERI), El Nozha 11843, Egypt. Hauptthemen laut MEDLINE: Microwaves, Respiration. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents an in-depth investigation of wearable microwave antenna sensors (MASs) used for vital sign detection (VSD) and lung water level (LWL) monitoring. The study looked at two different types of MASs, narrowband (NB) and ultra-wideband (UWB), to decide which one was better. Unlike recent wearable respiratory sensors, these antennas are simple in design, low-profile, and affordable. The narrowband sensor employs an offset-feed microstrip transmission line, which has a bandwidth of 240 MHz at −10 dB reflection coefficient for the textile substrate. The UWB microwave sensor uses a CPW-fed line to excite an unbalanced U-shaped radiator, offering an extended simulated operating bandwidth from 1.5 to 10 GHz with impedance matching ≤−10 dB. Both types of microwave sensors are designed on a flexible RO 3003 substrate and textile conductive fabric attached to a cotton substrate. The specific absorption rate (SAR) of the sensors is measured at different resonant frequencies on 1 g and 10 g of tissue, according to the IEEE C95.3 standard, and both sensors meet the standard limit of 1.6 W/kg and 2 W/kg, respectively. A simple peak-detection algorithm is used to demonstrate high accuracy in the detection of respiration, heartbeat, and lung water content. Based on the experimental results on a child and an adult volunteer, it can be concluded that UWB MASs offer superior performance when compared to NB sensors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrowavesRespirationHumansAdultChildHeart RateRespiratory RateLung

Stichwörter der Autor:innen

NBflexiblelung water level (LWL)microwave antenna sensor (MAS)specific absorption rate (SAR)textileultra-wideband (UWB) sensorvital sign detection (VSD)

Autor:innen und Institutionen

  • Microstrip Department, Electronics Research Institute (ERI), El Nozha 11843, Egypt.
  • Computer and Communication Department, Faculty of Engineering, Nahda University, Beni Suef 62746, Egypt.
  • Electrical Department, Faculty of Engineering and Technology, Badr University in Cairo, Badr 11829, Egypt.

ORCID-Profile: Anwer S Abd El-Hameed, Dalia M Elsheakh

Zitieren

APA

Abd El-Hameed, A. S., Elsheakh, D. M., Elashry, G. M., & Abdallah, E. A. (2024). A Comparative Study of Narrow/Ultra-Wideband Microwave Sensors for the Continuous Monitoring of Vital Signs and Lung Water Level. Sensors. https://doi.org/10.3390/s24051658

Vancouver

Abd El-Hameed AS, Elsheakh DM, Elashry GM, Abdallah EA. A Comparative Study of Narrow/Ultra-Wideband Microwave Sensors for the Continuous Monitoring of Vital Signs and Lung Water Level. Sensors. 2024. doi:10.3390/s24051658

BibTeX
@article{AbdElHameed2024,
  author = {Abd El-Hameed, Anwer S and Elsheakh, Dalia M and Elashry, Gomaa M and Abdallah, Esmat A},
  title = {A Comparative Study of Narrow/Ultra-Wideband Microwave Sensors for the Continuous Monitoring of Vital Signs and Lung Water Level},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24051658}
}
Kostenlos starten →