EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Inertial Measuring System to Evaluate Gait Parameters and Dynamic Alignments for Lower-Limb Amputation Subjects

Shao-Li Han, Meng-Lin Cai, Min-Chun Pan iD

Sensors · 2024

DOI: 10.3390/s24051519 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Shao-Li Han und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, National Central University, Taoyuan 32001, Taiwan. Hauptthemen laut MEDLINE: Amputees, Artificial Limbs. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Technology (Taiwan).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The study aims to construct an inertial measuring system for the application of amputee subjects wearing a prosthesis. A new computation scheme to process inertial data by installing seven wireless inertial sensors on the lower limbs was implemented and validated by comparing it with an optical motion capture system. We applied this system to amputees to verify its performance for gait analysis. The gait parameters are evaluated to objectively assess the amputees’ prosthesis-wearing status. The Madgwick algorithm was used in the study to correct the angular velocity deviation using acceleration data and convert it to quaternion. Further, the zero-velocity update method was applied to reconstruct patients’ walking trajectories. The combination of computed walking trajectory with pelvic and lower limb joint motion enables sketching the details of motion via a stickman that helps visualize and animate the walk and gait of a test subject. Five participants with above-knee (n = 2) and below-knee (n = 3) amputations were recruited for gait analysis. Kinematic parameters were evaluated during a walking test to assess joint alignment and overall gait characteristics. Our findings support the feasibility of employing simple algorithms to achieve accurate and precise joint angle estimation and gait parameters based on wireless inertial sensor data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AmputeesArtificial LimbsHumansGaitWalkingAmputation, SurgicalKneeKnee JointBiomechanical Phenomena

Stichwörter der Autor:innen

Madgwick filteringZUPTdynamic alignmentprosthetic gait analysiswireless inertial measuring system

Autor:innen und Institutionen

  • Department of Mechanical Engineering, National Central University, Taoyuan 32001, Taiwan.
  • Department of Physical Medicine and Rehabilitation, Changhua Christian Hospital, Changhua 500209, Taiwan.

ORCID-Profile: Min-Chun Pan

Förderung

  • Ministry of Science and Technology (Taiwan)

Zitieren

APA

Han, S. L., Cai, M. L., & Pan, M. C. (2024). Inertial Measuring System to Evaluate Gait Parameters and Dynamic Alignments for Lower-Limb Amputation Subjects. Sensors. https://doi.org/10.3390/s24051519

Vancouver

Han SL, Cai ML, Pan MC. Inertial Measuring System to Evaluate Gait Parameters and Dynamic Alignments for Lower-Limb Amputation Subjects. Sensors. 2024. doi:10.3390/s24051519

BibTeX
@article{Han2024,
  author = {Han, Shao-Li and Cai, Meng-Lin and Pan, Min-Chun},
  title = {Inertial Measuring System to Evaluate Gait Parameters and Dynamic Alignments for Lower-Limb Amputation Subjects},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24051519}
}
Kostenlos starten →