EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Time Delay Study of Ultrasonic Gas Flowmeters Based on VMD–Hilbert Spectrum and Cross-Correlation

Lingcai Kong, Liang Zhang, Hulin Guo, Ning Zhao iD, Xinhu Xu

Sensors · 23.02.2024 · 24 (5) · 1462

DOI: 10.3390/s24051462 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 23.02.2024. Verfasst von Lingcai Kong und 4 weiteren Autor:innen. Beteiligte Einrichtung: Thermometry Devision, National Institute of Metrology, Beijing 100029, China. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research on the second generation of acoustic method based flue flow field metering technolo-gy(Liang Zhang), Research and demonstration of monitoring and measurement methods for carbon dioxide emis-sions from the cement industry(Liang Zhang), research on the second generation of acoustic method based flue flow field metering technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The accuracy of ultrasonic flowmeter time delay measurement is directly affected by the processing method of the ultrasonic echo signal. This paper proposes a method for estimating the time delay of the ultrasonic gas flowmeter based on the Variational Mode Decomposition (VMD)–Hilbert Spectrum and Cross-Correlation (CC). The method improves the accuracy of the ultrasonic gas flowmeter by enhancing the quality of the echo signal. To denoise forward and reverse ultrasonic echo signals collected at various wind speeds, a Butterworth filter is initially used. The ultrasonic echo signals are then analyzed by Empirical Mode De-composition (EMD) and VMD analysis to obtain the Intrinsic Mode Function (IMF) containing distinct center frequencies, respectively. The Hilbert spectrum time–frequency diagram is used to evaluate the results of the VMD and EMD decompositions. It is found that the IMF decomposed by VMD has a better filtering performance and better anti-interference performance. Therefore, the IMF with a better effect is selected for signal reconstruction. The ultrasonic time delay is then calculated using the Cross-Correlation algorithm. The self-developed ultrasonic gas flowmeter was tested on the experimental platform of the gas flow standard devices using this signal processing method. The results show a maximum indication error of 0.84% within the flow range of 60–606 m3/h, with a repeatability of no more than 0.29%. These results meet the 1-level accuracy requirements as outlined in the national ultrasonic flowmeters calibration regulation JJG1030-2007.

Schlagwörter

Stichwörter der Autor:innen

Hilbert transformVMDsignal processingtime delayultrasonic gas flowmeter

Autor:innen und Institutionen

  • Thermometry Devision, National Institute of Metrology, Beijing 100029, China.
  • School of Quality and Technical Supervision, Hebei University, Baoding 071000, China.
  • Zhengzhou Institute of Metrology, Zhengzhou 450001, China.

ORCID-Profile: Ning Zhao

Förderung

  • Research on the second generation of acoustic method based flue flow field metering technolo-gy(Liang Zhang)
  • Research and demonstration of monitoring and measurement methods for carbon dioxide emis-sions from the cement industry(Liang Zhang)
  • research on the second generation of acoustic method based flue flow field metering technology
  • research and demonstration of monitoring and measurement methods for carbon dioxide emissions from the cement industry

Zitieren

APA

Kong, L., Zhang, L., Guo, H., Zhao, N., & Xu, X. (2024). Time Delay Study of Ultrasonic Gas Flowmeters Based on VMD–Hilbert Spectrum and Cross-Correlation. Sensors, 24(5), 1462. https://doi.org/10.3390/s24051462

Vancouver

Kong L, Zhang L, Guo H, Zhao N, Xu X. Time Delay Study of Ultrasonic Gas Flowmeters Based on VMD–Hilbert Spectrum and Cross-Correlation. Sensors. 2024;24(5):1462. doi:10.3390/s24051462

BibTeX
@article{Kong2024,
  author = {Kong, Lingcai and Zhang, Liang and Guo, Hulin and Zhao, Ning and Xu, Xinhu},
  title = {Time Delay Study of Ultrasonic Gas Flowmeters Based on VMD–Hilbert Spectrum and Cross-Correlation},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {5},
  pages = {1462},
  doi = {10.3390/s24051462}
}
Kostenlos starten →