IMU-Based Fitness Activity Recognition Using CNNs for Time Series Classification
Sensors · 2024
DOI: 10.3390/s24030742 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Philipp Niklas Müller und 3 weiteren Autor:innen. Beteiligte Einrichtung: Serious Games Group, Technical University of Darmstadt, 64289 Darmstadt, Germany. Hauptthemen laut MEDLINE: Neural Networks, Computer, Machine Learning. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Mobile fitness applications provide the opportunity to show users real-time feedback on their current fitness activity. For such applications, it is essential to accurately track the user’s current fitness activity using available mobile sensors, such as inertial measurement units (IMUs). Convolutional neural networks (CNNs) have been shown to produce strong results in different time series classification tasks, including the recognition of daily living activities. However, fitness activities can present unique challenges to the human activity recognition task (HAR), including greater similarity between individual activities and fewer available data for model training. In this paper, we evaluate the applicability of CNNs to the fitness activity recognition task (FAR) using IMU data and determine the impact of input data size and sensor count on performance. For this purpose, we adapted three existing CNN architectures to the FAR task and designed a fourth CNN variant, which we call the scaling fully convolutional network (Scaling-FCN). We designed a preprocessing pipeline and recorded a running exercise data set with 20 participants, in which we evaluated the respective recognition performances of the four networks, comparing them with three traditional machine learning (ML) methods commonly used in HAR. Although CNN architectures achieve at least 94% test accuracy in all scenarios, two traditional ML architectures surpass them in the default scenario, with support vector machines (SVMs) achieving 99.00 ± 0.34% test accuracy. The removal of all sensors except one foot sensor reduced the performance of traditional ML architectures but improved the performance of CNN architectures on our data set, with our Scaling-FCN reaching the highest accuracy of 99.86 ± 0.11% on the test set. Our results suggest that CNNs are generally well suited for fitness activity recognition, and noticeable performance improvements can be achieved if sensors are dropped selectively, although traditional ML architectures can still compete with or even surpass CNNs when favorable input data are utilized.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Serious Games Group, Technical University of Darmstadt, 64289 Darmstadt, Germany.
ORCID-Profile: Philipp Niklas Müller, Philipp Achenbach, Stefan Göbel
Zitieren
APA
Müller, P. N., Müller, A. J., Achenbach, P., & Göbel, S. (2024). IMU-Based Fitness Activity Recognition Using CNNs for Time Series Classification. Sensors. https://doi.org/10.3390/s24030742
Vancouver
Müller PN, Müller AJ, Achenbach P, Göbel S. IMU-Based Fitness Activity Recognition Using CNNs for Time Series Classification. Sensors. 2024. doi:10.3390/s24030742
BibTeX
@article{Mller2024,
author = {Müller, Philipp Niklas and Müller, Alexander Josef and Achenbach, Philipp and Göbel, Stefan},
title = {IMU-Based Fitness Activity Recognition Using CNNs for Time Series Classification},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24030742}
}
EUVIMED