EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessment of the Performance of Ultrasonography for Detecting Myofascial Trigger Points

Han-Yu Chen iD, Chang-Zern Hong, Yueh-Ling Hsieh iD

Sensors · 2024

DOI: 10.3390/s24030718 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Han-Yu Chen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Therapy, Hungkuang University, Taichung 433304, Taiwan. Hauptthemen laut MEDLINE: Trigger Points, Myofascial Pain Syndromes. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Needle electromyogram (EMG) research has suggested that endplate noise (EPN) is a characteristic of myofascial trigger points (MTrPs). Although several studies have observed MTrPs through ultrasonography, whether they are hyperechoic or hypoechoic in ultrasound images is still controversial. Therefore, this study determined the echogenicity of MTrP ultrasonography. In stage 1, the MTrP of rat masseter muscle was identified through palpation and marked. Needle EMG was performed to detect the presence of EPN. When EPN was detected, ultrasound scans and indwelling needles were used to identify the nodule with a different grayscale relative to that of its surrounding tissue, and the echogenicity of the identified MTrP was determined. In stage 2, these steps were reversed. An ultrasound scan was performed to detect the nodule at the marked site, and an EMG needle was inserted into the nodule to detect EPN. There were 178 recordings in each stage, obtained from 45 rats. The stage 1 results indicate that the MTrPs in ultrasound images were hypoechoic with a 100% sensitivity of assessment. In stage 2, the accuracy and precision of MTrP detection through ultrasonography were 89.9% and 89.2%, respectively. The results indicate that ultrasonography produces highly accurate and precise MTrP detection results.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Trigger PointsMyofascial Pain SyndromesRatsAnimalsUltrasonographyElectromyographyNeedles

Stichwörter der Autor:innen

echogenicityendplate noisemyofascial trigger pointultrasonography

Autor:innen und Institutionen

  • Department of Physical Therapy, Hungkuang University, Taichung 433304, Taiwan.
  • Taiwan Myopain Academic Association, Tainan 704032, Taiwan.
  • Department of Physical Therapy, China Medical University, Taichung 406040, Taiwan.

ORCID-Profile: Han-Yu Chen, Yueh-Ling Hsieh

Zitieren

APA

Chen, H. Y., Hong, C. Z., & Hsieh, Y. L. (2024). Assessment of the Performance of Ultrasonography for Detecting Myofascial Trigger Points. Sensors. https://doi.org/10.3390/s24030718

Vancouver

Chen HY, Hong CZ, Hsieh YL. Assessment of the Performance of Ultrasonography for Detecting Myofascial Trigger Points. Sensors. 2024. doi:10.3390/s24030718

BibTeX
@article{Chen2024,
  author = {Chen, Han-Yu and Hong, Chang-Zern and Hsieh, Yueh-Ling},
  title = {Assessment of the Performance of Ultrasonography for Detecting Myofascial Trigger Points},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24030718}
}
Kostenlos starten →