Evaluating Accuracy in Five Commercial Sleep-Tracking Devices Compared to Research-Grade Actigraphy and Polysomnography
Sensors · 19.01.2024 · 24 (2) · 635
DOI: 10.3390/s24020635 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 19.01.2024. Verfasst von Kyle A Kainec und 5 weiteren Autor:innen. Beteiligte Einrichtung: Neuroscience & Behavior Program, French Hall, University of Massachusetts Amherst, 230 Stockbridge Road, Amherst, MA 01003, USA. Hauptthemen laut MEDLINE: Actigraphy, Sleep Wake Disorders. Die Arbeit wurde bisher 79-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Commonwealth Honors College at the University of Massachusetts.
Abstract (Originalsprache)
The development of consumer sleep-tracking technologies has outpaced the scientific evaluation of their accuracy. In this study, five consumer sleep-tracking devices, research-grade actigraphy, and polysomnography were used simultaneously to monitor the overnight sleep of fifty-three young adults in the lab for one night. Biases and limits of agreement were assessed to determine how sleep stage estimates for each device and research-grade actigraphy differed from polysomnography-derived measures. Every device, except the Garmin Vivosmart, was able to estimate total sleep time comparably to research-grade actigraphy. All devices overestimated nights with shorter wake times and underestimated nights with longer wake times. For light sleep, absolute bias was low for the Fitbit Inspire and Fitbit Versa. The Withings Mat and Garmin Vivosmart overestimated shorter light sleep and underestimated longer light sleep. The Oura Ring underestimated light sleep of any duration. For deep sleep, bias was low for the Withings Mat and Garmin Vivosmart while other devices overestimated shorter and underestimated longer times. For REM sleep, bias was low for all devices. Taken together, these results suggest that proportional bias patterns in consumer sleep-tracking technologies are prevalent and could have important implications for their overall accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Neuroscience & Behavior Program, French Hall, University of Massachusetts Amherst, 230 Stockbridge Road, Amherst, MA 01003, USA.
- Institute for Applied Life Sciences, Life Science Laboratories, University of Massachusetts Amherst, 240 Thatcher Road, Amherst, MA 01003, USA.
- Department of Psychological and Brain Sciences, Tobin Hall, University of Massachusetts Amherst, 135 Hicks Way, Amherst, MA 01003, USA.
ORCID-Profile: Kyle A Kainec
Förderung
- Commonwealth Honors College at the University of Massachusetts
Zitieren
APA
Kainec, K. A., Caccavaro, J., Barnes, M., Hoff, C., Berlin, A., & Spencer, R. M. C. (2024). Evaluating Accuracy in Five Commercial Sleep-Tracking Devices Compared to Research-Grade Actigraphy and Polysomnography. Sensors, 24(2), 635. https://doi.org/10.3390/s24020635
Vancouver
Kainec KA, Caccavaro J, Barnes M, Hoff C, Berlin A, Spencer RMC. Evaluating Accuracy in Five Commercial Sleep-Tracking Devices Compared to Research-Grade Actigraphy and Polysomnography. Sensors. 2024;24(2):635. doi:10.3390/s24020635
BibTeX
@article{Kainec2024,
author = {Kainec, Kyle A and Caccavaro, Jamie and Barnes, Morgan and Hoff, Chloe and Berlin, Annika and Spencer, Rebecca M C},
title = {Evaluating Accuracy in Five Commercial Sleep-Tracking Devices Compared to Research-Grade Actigraphy and Polysomnography},
journal = {Sensors},
year = {2024},
volume = {24},
number = {2},
pages = {635},
doi = {10.3390/s24020635}
}
EUVIMED