Towards a Miniaturized Photoacoustic Sensor for Transcutaneous CO2 Monitoring
Sensors · 11.01.2024 · 24 (2) · 457
DOI: 10.3390/s24020457 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 11.01.2024. Verfasst von Mahmoud El-Safoury und 4 weiteren Autor:innen. Beteiligte Einrichtung: Fraunhofer Institute for Physical Measurement Techniques IPM, 79110 Freiburg im Breisgau, Germany. Hauptthemen laut MEDLINE: Carbon Dioxide, Household Articles. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fraunhofer Internal Programs.
Abstract (Originalsprache)
A photoacoustic sensor system (PAS) intended for carbon dioxide (CO2) blood gas detection is presented. The development focuses on a photoacoustic (PA) sensor based on the so-called two-chamber principle, i.e., comprising a measuring cell and a detection chamber. The aim is the reliable continuous monitoring of transcutaneous CO2 values, which is very important, for example, in intensive care unit patient monitoring. An infrared light-emitting diode (LED) with an emission peak wavelength at 4.3 µm was used as a light source. A micro-electro-mechanical system (MEMS) microphone and the target gas CO2 are inside a hermetically sealed detection chamber for selective target gas detection. Based on conducted simulations and measurement results in a laboratory setup, a miniaturized PA CO2 sensor with an absorption path length of 2.0 mm and a diameter of 3.0 mm was developed for the investigation of cross-sensitivities, detection limit, and signal stability and was compared to a commercial infrared CO2 sensor with a similar measurement range. The achieved detection limit of the presented PA CO2 sensor during laboratory tests is 1 vol. % CO2. Compared to the commercial sensor, our PA sensor showed less influences of humidity and oxygen on the detected signal and a faster response and recovery time. Finally, the developed sensor system was fixed to the skin of a test person, and an arterialization time of 181 min could be determined.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Fraunhofer Institute for Physical Measurement Techniques IPM, 79110 Freiburg im Breisgau, Germany.
- Department of Microsystems Engineering-Institut für Mikrosystemtechnik (IMTEK), University of Freiburg, 79110 Freiburg im Breisgau, Germany.
ORCID-Profile: Katrin Schmitt
Förderung
- Fraunhofer Internal Programs
Zitieren
APA
El-Safoury, M., Weber, C., Yassine, H., Wöllenstein, J., & Schmitt, K. (2024). Towards a Miniaturized Photoacoustic Sensor for Transcutaneous CO2 Monitoring. Sensors, 24(2), 457. https://doi.org/10.3390/s24020457
Vancouver
El-Safoury M, Weber C, Yassine H, Wöllenstein J, Schmitt K. Towards a Miniaturized Photoacoustic Sensor for Transcutaneous CO2 Monitoring. Sensors. 2024;24(2):457. doi:10.3390/s24020457
BibTeX
@article{ElSafoury2024,
author = {El-Safoury, Mahmoud and Weber, Christian and Yassine, Hassan and Wöllenstein, Jürgen and Schmitt, Katrin},
title = {Towards a Miniaturized Photoacoustic Sensor for Transcutaneous CO2 Monitoring},
journal = {Sensors},
year = {2024},
volume = {24},
number = {2},
pages = {457},
doi = {10.3390/s24020457}
}
EUVIMED