Calibration of Ring Oscillator-Based Integrated Temperature Sensors for Power Management Systems
Sensors · 11.01.2024 · 24 (2) · 440
DOI: 10.3390/s24020440 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 11.01.2024. Verfasst von Nader El-Zarif und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Polytechnique Montreal, Montreal, QC H3T 1J4, Canada. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Mathematics of Information Technology and Complex Systems (MITACS) funding agency.
Abstract (Originalsprache)
This paper details the development and validation of a temperature sensing methodology using an un-trimmed oscillator-based integrated sensor implemented in the 0.18-μm SOI XFAB process, with a focus on thermal monitoring in system-on-chip (SoC) based DC-DC converters. Our study identifies a quadratic relationship between the oscillator output frequency and temperature, which forms the basis of our proposed calibration mechanism. This mechanism aims at mitigating process variation effects, enabling accurate temperature-to-frequency mapping. Our research proposes and characterizes several trimming-free calibration techniques, covering a spectrum from zero to thirty-one frequency-temperature measurement points. Notably, the Corrected One-Point calibration method, requiring only a single ambient temperature measurement, emerges as a practical solution that removes the need for a temperature chamber. This method, after adjustment, successfully reduces the maximum error to within ±2.95 °C. Additionally, the Two-Point calibration method demonstrates improved precision with a maximum positive error of +1.56 °C at −15 °C and a maximum negative error of −3.13 °C at +10 °C (R2 value of 0.9958). The Three-Point calibration method performed similarly, yielding an R2 value of 0.9956. The findings of this study indicate that competitive results in temperature sensor calibration can be achieved without circuit trimming, offering a viable alternative or a complementary approach to traditional trimming techniques.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Engineering, Polytechnique Montreal, Montreal, QC H3T 1J4, Canada.
- Department of Computer Science and Engineering, University of Quebec in Outaouais, Gatineau, QC J8X 3X7, Canada.
- Department of Computer Science, University of Quebec in Montreal, Montreal, QC H3C 3P8, Canada.
ORCID-Profile: Nader El-Zarif, Mohamed Ali, Ahmad Hassan, Aziz Oukaira
Förderung
- Mathematics of Information Technology and Complex Systems (MITACS) funding agency
Zitieren
APA
El-Zarif, N., Amer, M., Ali, M., Hassan, A., Oukaira, A., Fayomi, C. J. B., & Savaria, Y. (2024). Calibration of Ring Oscillator-Based Integrated Temperature Sensors for Power Management Systems. Sensors, 24(2), 440. https://doi.org/10.3390/s24020440
Vancouver
El-Zarif N, Amer M, Ali M, Hassan A, Oukaira A, Fayomi CJB, et al. Calibration of Ring Oscillator-Based Integrated Temperature Sensors for Power Management Systems. Sensors. 2024;24(2):440. doi:10.3390/s24020440
BibTeX
@article{ElZarif2024,
author = {El-Zarif, Nader and Amer, Mostafa and Ali, Mohamed and Hassan, Ahmad and Oukaira, Aziz and Fayomi, Christian Jesus B and Savaria, Yvon},
title = {Calibration of Ring Oscillator-Based Integrated Temperature Sensors for Power Management Systems},
journal = {Sensors},
year = {2024},
volume = {24},
number = {2},
pages = {440},
doi = {10.3390/s24020440}
}