EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Multi-Channel Soft Dry Electrodes for Electrocardiography Acquisition in the Ear Region

Patrick van der Heijden iD, Camille Gilbert iD, Samira Jafari, Mattia Alberto Lucchini

Sensors · 2024

DOI: 10.3390/s24020420 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Patrick van der Heijden und 3 weiteren Autor:innen. Beteiligte Einrichtung: imec The Netherlands/Holst Centre, 5656 AE Eindhoven, The Netherlands. Hauptthemen laut MEDLINE: Ear Canal, Electrocardiography. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In-ear acquisition of physiological signals, such as electromyography (EMG), electrooculography (EOG), electroencephalography (EEG), and electrocardiography (ECG), is a promising approach to mobile health (mHealth) due to its non-invasive and user-friendly nature. By providing a convenient and comfortable means of physiological signal monitoring, in-ear signal acquisition could potentially increase patient compliance and engagement with mHealth applications. The development of reliable and comfortable soft dry in-ear electrode systems could, therefore, have significant implications for both mHealth and human–machine interface (HMI) applications. This research evaluates the quality of the ECG signal obtained with soft dry electrodes inserted in the ear canal. An earplug with six soft dry electrodes distributed around its perimeter was designed for this study, allowing for the analysis of the signal coming from each electrode independently with respect to a common reference placed at different positions on the body of the participants. An analysis of the signals in comparison with a reference signal measured on the upper right chest (RA) and lower left chest (LL) was performed. The results show three typical behaviors for the in-ear electrodes. Some electrodes have a high correlation with the reference signal directly after inserting the earplug, other electrodes need a settling time of typically 1–3 min, and finally, others never have a high correlation. The SoftPulseTM electrodes used in this research have been proven to be perfectly capable of measuring physiological signals, paving the way for their use in mHealth or HMI applications. The use of multiple electrodes distributed in the ear canal has the advantage of allowing a more reliable acquisition by intelligently selecting the signal acquisition locations or allowing a better spatial resolution for certain applications by processing these signals independently.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ear CanalElectrocardiographyHumansElectrodesElectroencephalographyElectromyography

Stichwörter der Autor:innen

ear-based wearableelectrocardiogramelectrodesin-ear biosignalsmobile-health

Autor:innen und Institutionen

  • imec The Netherlands/Holst Centre, 5656 AE Eindhoven, The Netherlands.
  • Dätwyler Schweiz AG, 6467 Schattdorf, Switzerland.

ORCID-Profile: Patrick van der Heijden, Camille Gilbert

Zitieren

APA

van der Heijden, P., Gilbert, C., Jafari, S., & Lucchini, M. A. (2024). Multi-Channel Soft Dry Electrodes for Electrocardiography Acquisition in the Ear Region. Sensors. https://doi.org/10.3390/s24020420

Vancouver

van der Heijden P, Gilbert C, Jafari S, Lucchini MA. Multi-Channel Soft Dry Electrodes for Electrocardiography Acquisition in the Ear Region. Sensors. 2024. doi:10.3390/s24020420

BibTeX
@article{vanderHeijden2024,
  author = {van der Heijden, Patrick and Gilbert, Camille and Jafari, Samira and Lucchini, Mattia Alberto},
  title = {Multi-Channel Soft Dry Electrodes for Electrocardiography Acquisition in the Ear Region},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24020420}
}
Kostenlos starten →