The Development of a Wearable Biofeedback System to Elicit Temporal Gait Asymmetry using Rhythmic Auditory Stimulation and an Assessment of Immediate Effects
Sensors · 2024
DOI: 10.3390/s24020400 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Aliaa Gouda und 1 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada. Hauptthemen laut MEDLINE: Biofeedback, Psychology, Wearable Electronic Devices. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council, Canadian Institute of Health Research, Natural Sciences and Engineering Research Council of Canada (NSERC) Postgraduate Scholarship.
Abstract (Originalsprache)
Temporal gait asymmetry (TGA) is commonly observed in individuals facing mobility challenges. Rhythmic auditory stimulation (RAS) can improve temporal gait parameters by promoting synchronization with external cues. While biofeedback for gait training, providing real-time feedback based on specific gait parameters measured, has been proven to successfully elicit changes in gait patterns, RAS-based biofeedback as a treatment for TGA has not been explored. In this study, a wearable RAS-based biofeedback gait training system was developed to measure temporal gait symmetry in real time and deliver RAS accordingly. Three different RAS-based biofeedback strategies were compared: open- and closed-loop RAS at constant and variable target levels. The main objective was to assess the ability of the system to induce TGA with able-bodied (AB) participants and evaluate and compare each strategy. With all three strategies, temporal symmetry was significantly altered compared to the baseline, with the closed-loop strategy yielding the most significant changes when comparing at different target levels. Speed and cadence remained largely unchanged during RAS-based biofeedback gait training. Setting the metronome to a target beyond the intended target may potentially bring the individual closer to their symmetry target. These findings hold promise for developing personalized and effective gait training interventions to address TGA in patient populations with mobility limitations using RAS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada.
- Bloorview Research Institute, Holland Bloorview Kids Rehabilitation Hospital, Toronto, ON M4G 1R8, Canada.
ORCID-Profile: Aliaa Gouda, Jan Andrysek
Förderung
- Natural Sciences and Engineering Research Council
- Canadian Institute of Health Research
- Natural Sciences and Engineering Research Council of Canada (NSERC) Postgraduate Scholarship
- Canadian Institutes of Health Research
- Natural Sciences and Engineering Research Council (NSERC) Discovery
Zitieren
APA
Gouda, A., & Andrysek, J. (2024). The Development of a Wearable Biofeedback System to Elicit Temporal Gait Asymmetry using Rhythmic Auditory Stimulation and an Assessment of Immediate Effects. Sensors. https://doi.org/10.3390/s24020400
Vancouver
Gouda A, Andrysek J. The Development of a Wearable Biofeedback System to Elicit Temporal Gait Asymmetry using Rhythmic Auditory Stimulation and an Assessment of Immediate Effects. Sensors. 2024. doi:10.3390/s24020400
BibTeX
@article{Gouda2024,
author = {Gouda, Aliaa and Andrysek, Jan},
title = {The Development of a Wearable Biofeedback System to Elicit Temporal Gait Asymmetry using Rhythmic Auditory Stimulation and an Assessment of Immediate Effects},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24020400}
}
EUVIMED