Design, Optimization, and Experimental Evaluation of Slow Light Generated by π-Phase-Shifted Fiber Bragg Grating for Use in Sensing Applications
Sensors · 06.01.2024 · 24 (2) · 340
DOI: 10.3390/s24020340 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 06.01.2024. Verfasst von Matúš Vaňko und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Multimedia and Information-Communication Technologies, Faculty of Electrical Engineering and Information Technology, University of Žili…. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Slovak Research and Development Agency, Slovak Grant Agency (VEGA).
Abstract (Originalsprache)
This paper describes design, theoretical analysis, and experimental evaluation of a π-Phase-Shifted Fiber Bragg Grating (π-PSFBG) inscribed in the standard telecom fiber for slow light generation. At first, the grating was designed for its use in the reflection mode with a central wavelength of 1552 nm and a pass band width of less than 100 pm. The impact of fabrication imperfections was experimentally investigated and compared to model predictions. The optical spectra obtained experimentally show that the spectral region used for slow light generation is narrower (less than 10 pm), thus allowing for too-low levels of slow light optical-output power. In the next step, the optimization of the grating design was conducted to account for fabrication errors, to improve the grating’s spectral behavior and its temporal performance, and to widen the spectral interval for slow light generation in the grating’s transmission mode. The targeted central wavelength was 1553 nm. The π-PSFBG was then commercially fabricated, and the achieved parameters were experimentally investigated. For the region of (1551–1554) nm, a 15-fold increase in the grating’s pass band width was achieved. We have shown that a pair of retarded optical pulses were generated. The measured group delay was found to be ~10.5 ps (compared to 19 ps predicted by the model). The π-PSFBG operating in its transmission mode has the potential to operate as tunable delay line for applications in RF photonics, ultra-fast signal processing, and optical communications, where tunable high precision delay lines are highly desirable. The π-PSFBG can be designed and used for the generation of variable group delays from tens to hundreds of ps, depending on application needs.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Multimedia and Information-Communication Technologies, Faculty of Electrical Engineering and Information Technology, University of Žilina, Univerzitná 8215/1, 010 26 Žilina, Slovakia.
- Electronic and Electrical Engineering Department, University of Strathclyde, 204 George Street, Glasgow G1 1XW, UK.
- Institute of Aurel Stodola, Faculty of Electrical Engineering and Information Technology, University of Žilina, Komenského 843, 031 01 Liptovský Mikuláš, Slovakia.
ORCID-Profile: Ivan Glesk
Förderung
- Slovak Research and Development Agency
- Slovak Grant Agency (VEGA)
Zitieren
APA
Vaňko, M., Glesk, I., Müllerová, J., Dubovan, J., & Dado, M. (2024). Design, Optimization, and Experimental Evaluation of Slow Light Generated by π-Phase-Shifted Fiber Bragg Grating for Use in Sensing Applications. Sensors, 24(2), 340. https://doi.org/10.3390/s24020340
Vancouver
Vaňko M, Glesk I, Müllerová J, Dubovan J, Dado M. Design, Optimization, and Experimental Evaluation of Slow Light Generated by π-Phase-Shifted Fiber Bragg Grating for Use in Sensing Applications. Sensors. 2024;24(2):340. doi:10.3390/s24020340
BibTeX
@article{Vako2024,
author = {Vaňko, Matúš and Glesk, Ivan and Müllerová, Jarmila and Dubovan, Jozef and Dado, Milan},
title = {Design, Optimization, and Experimental Evaluation of Slow Light Generated by π-Phase-Shifted Fiber Bragg Grating for Use in Sensing Applications},
journal = {Sensors},
year = {2024},
volume = {24},
number = {2},
pages = {340},
doi = {10.3390/s24020340}
}