EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Pneumatically Controlled Prosthetic Socket for Transfemoral Amputees

Kang-Ho Lee, Hyun-Seok Heo, Jeongmin Kim iD, Jang Hyuk Cho, Kyoung Tae Kim iD, Jeong-Yong Hur, Jang Hwan Kim, Yongkoo Lee

Sensors · 2023

DOI: 10.3390/s24010133 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Kang-Ho Lee und 7 weiteren Autor:innen. Beteiligte Einrichtung: Daegu Research Center for Medical Devices, Korea Institute of Machinery and Materials, Daegu 42994, Republic of Korea. Hauptthemen laut MEDLINE: Amputees, Artificial Limbs. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NK244D projects of the Korea Institute of Machinery and Materials.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Amputees typically experience changes in residual limb volume in their daily lives. It causes an uncomfortable fit of the socket by applying high pressure on the sensitive area of the residual limb or by loosening the socket. In this study, we developed a transfemoral prosthetic socket for above-the-knee amputees that ensures a good socket fit by maintaining uniform and constant contact pressure despite volume changes in the residual limb. The socket has two air bladders in the posterior femoral region, and the pneumatic controller is located on the tibia of the prosthesis. The pneumatic system aims to minimize unstable fitting of the socket and improve walking performance by inflating or deflating the air bladder. The developed socket autonomously maintains the air pressure inside the prosthetic socket at a steady-state error of 3 mmHg or less by adjusting the amount of air in the air bladder via closed-loop control. In the clinical trial, amputee participants walked on flat and inclined surfaces. The displacement between the residual limb and socket during the gait cycle was reduced by up to 33.4% after air injection into the socket. The inflatable bladder increased the knee flexion angle on the affected side, resulting in increased stride length and gait velocity. The pneumatic socket provides a stable and comfortable walking experience not only when walking on flat ground but also on slopes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AmputeesArtificial LimbsHumansGaitWalkingExtremities

Stichwörter der Autor:innen

air bladderamputeepneumaticprosthesistransfemoral socket

Autor:innen und Institutionen

  • Daegu Research Center for Medical Devices, Korea Institute of Machinery and Materials, Daegu 42994, Republic of Korea.
  • Shinsegae Prosthetic Center, Daegu 41710, Republic of Korea.
  • Department of Rehabilitation Medicine, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu 42601, Republic of Korea.
  • Department of Rehabilitation Technology, Graduate School of Hanseo University, Seosan 31962, Republic of Korea.

ORCID-Profile: Jeongmin Kim, Kyoung Tae Kim

Förderung

  • NK244D projects of the Korea Institute of Machinery and Materials

Zitieren

APA

Lee, K. H., Heo, H. S., Kim, J., Cho, J. H., Kim, K. T., Hur, J. Y., Kim, J. H., & Lee, Y. (2023). A Pneumatically Controlled Prosthetic Socket for Transfemoral Amputees. Sensors. https://doi.org/10.3390/s24010133

Vancouver

Lee KH, Heo HS, Kim J, Cho JH, Kim KT, Hur JY, et al. A Pneumatically Controlled Prosthetic Socket for Transfemoral Amputees. Sensors. 2023. doi:10.3390/s24010133

BibTeX
@article{Lee2023,
  author = {Lee, Kang-Ho and Heo, Hyun-Seok and Kim, Jeongmin and Cho, Jang Hyuk and Kim, Kyoung Tae and Hur, Jeong-Yong and Kim, Jang Hwan and Lee, Yongkoo},
  title = {A Pneumatically Controlled Prosthetic Socket for Transfemoral Amputees},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s24010133}
}
Kostenlos starten →