Validity of AI-Based Gait Analysis for Simultaneous Measurement of Bilateral Lower Limb Kinematics Using a Single Video Camera
Sensors · 13.12.2023 · 23 (24) · 9799
DOI: 10.3390/s23249799 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 13.12.2023. Verfasst von Takumi Ino und 6 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Health Sciences, Hokkaido University, Sapporo 0600812, Japan. Hauptthemen laut MEDLINE: Gait Analysis, Artificial Intelligence. Die Arbeit wurde bisher 44-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JSPS KAKENHI.
Abstract (Originalsprache)
Accuracy validation of gait analysis using pose estimation with artificial intelligence (AI) remains inadequate, particularly in objective assessments of absolute error and similarity of waveform patterns. This study aimed to clarify objective measures for absolute error and waveform pattern similarity in gait analysis using pose estimation AI (OpenPose). Additionally, we investigated the feasibility of simultaneous measuring both lower limbs using a single camera from one side. We compared motion analysis data from pose estimation AI using video footage that was synchronized with a three-dimensional motion analysis device. The comparisons involved mean absolute error (MAE) and the coefficient of multiple correlation (CMC) to compare the waveform pattern similarity. The MAE ranged from 2.3 to 3.1° on the camera side and from 3.1 to 4.1° on the opposite side, with slightly higher accuracy on the camera side. Moreover, the CMC ranged from 0.936 to 0.994 on the camera side and from 0.890 to 0.988 on the opposite side, indicating a “very good to excellent” waveform similarity. Gait analysis using a single camera revealed that the precision on both sides was sufficiently robust for clinical evaluation, while measurement accuracy was slightly superior on the camera side.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Graduate School of Health Sciences, Hokkaido University, Sapporo 0600812, Japan.
- Department of Physical Therapy, Faculty of Health Sciences, Hokkaido University of Science, Sapporo 0068585, Japan.
- Faculty of Health Sciences, Hokkaido University, Sapporo 0600812, Japan.
- Department of Information and Computer Science, Faculty of Engineering, Hokkaido University of Science, Sapporo 0068585, Japan.
ORCID-Profile: Takumi Ino, Mina Samukawa, Tomoya Ishida, Yuta Koshino
Förderung
- JSPS KAKENHI
Zitieren
APA
Ino, T., Samukawa, M., Ishida, T., Wada, N., Koshino, Y., Kasahara, S., & Tohyama, H. (2023). Validity of AI-Based Gait Analysis for Simultaneous Measurement of Bilateral Lower Limb Kinematics Using a Single Video Camera. Sensors, 23(24), 9799. https://doi.org/10.3390/s23249799
Vancouver
Ino T, Samukawa M, Ishida T, Wada N, Koshino Y, Kasahara S, et al. Validity of AI-Based Gait Analysis for Simultaneous Measurement of Bilateral Lower Limb Kinematics Using a Single Video Camera. Sensors. 2023;23(24):9799. doi:10.3390/s23249799
BibTeX
@article{Ino2023,
author = {Ino, Takumi and Samukawa, Mina and Ishida, Tomoya and Wada, Naofumi and Koshino, Yuta and Kasahara, Satoshi and Tohyama, Harukazu},
title = {Validity of AI-Based Gait Analysis for Simultaneous Measurement of Bilateral Lower Limb Kinematics Using a Single Video Camera},
journal = {Sensors},
year = {2023},
volume = {23},
number = {24},
pages = {9799},
doi = {10.3390/s23249799}
}
EUVIMED