A Robust Approach Assisted by Signal Quality Assessment for Fetal Heart Rate Estimation from Doppler Ultrasound Signal
Sensors · 2023
DOI: 10.3390/s23249698 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Xintong Shi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Science and Technology, Keio University, Yokohama 223-8522, Japan. Hauptthemen laut MEDLINE: Heart Rate, Fetal, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Atom Medical Corporation.
Abstract (Originalsprache)
Fetal heart rate (FHR) monitoring, typically using Doppler ultrasound (DUS) signals, is an important technique for assessing fetal health. In this work, we develop a robust DUS-based FHR estimation approach complemented by DUS signal quality assessment (SQA) based on unsupervised representation learning in response to the drawbacks of previous DUS-based FHR estimation and DUS SQA methods. We improve the existing FHR estimation algorithm based on the autocorrelation function (ACF), which is the most widely used method for estimating FHR from DUS signals. Short-time Fourier transform (STFT) serves as a signal pre-processing technique that allows the extraction of both temporal and spectral information. In addition, we utilize double ACF calculations, employing the first one to determine an appropriate window size and the second one to estimate the FHR within changing windows. This approach enhances the robustness and adaptability of the algorithm. Furthermore, we tackle the challenge of low-quality signals impacting FHR estimation by introducing a DUS SQA method based on unsupervised representation learning. We employ a variational autoencoder (VAE) to train representations of pre-processed fetal DUS data and aggregate them into a signal quality index (SQI) using a self-organizing map (SOM). By incorporating the SQI and Kalman filter (KF), we refine the estimated FHRs, minimizing errors in the estimation process. Experimental results demonstrate that our proposed approach outperforms conventional methods in terms of accuracy and robustness.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Graduate School of Science and Technology, Keio University, Yokohama 223-8522, Japan.
- Department of Information and Computer Science, Keio University, Yokohama 223-8522, Japan.
- Atom Medical Co., Tokyo 113-0021, Japan.
ORCID-Profile: Xintong Shi, Tomoaki Ohtsuki
Förderung
- Atom Medical Corporation
Zitieren
APA
Shi, X., Niida, N., Yamamoto, K., Ohtsuki, T., Matsui, Y., & Owada, K. (2023). A Robust Approach Assisted by Signal Quality Assessment for Fetal Heart Rate Estimation from Doppler Ultrasound Signal. Sensors. https://doi.org/10.3390/s23249698
Vancouver
Shi X, Niida N, Yamamoto K, Ohtsuki T, Matsui Y, Owada K. A Robust Approach Assisted by Signal Quality Assessment for Fetal Heart Rate Estimation from Doppler Ultrasound Signal. Sensors. 2023. doi:10.3390/s23249698
BibTeX
@article{Shi2023,
author = {Shi, Xintong and Niida, Natsuho and Yamamoto, Kohei and Ohtsuki, Tomoaki and Matsui, Yutaka and Owada, Kazunari},
title = {A Robust Approach Assisted by Signal Quality Assessment for Fetal Heart Rate Estimation from Doppler Ultrasound Signal},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23249698}
}
EUVIMED