EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Robust Approach Assisted by Signal Quality Assessment for Fetal Heart Rate Estimation from Doppler Ultrasound Signal

Xintong Shi iD, Natsuho Niida, Kohei Yamamoto, Tomoaki Ohtsuki iD, Yutaka Matsui, Kazunari Owada

Sensors · 2023

DOI: 10.3390/s23249698 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Xintong Shi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Science and Technology, Keio University, Yokohama 223-8522, Japan. Hauptthemen laut MEDLINE: Heart Rate, Fetal, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Atom Medical Corporation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fetal heart rate (FHR) monitoring, typically using Doppler ultrasound (DUS) signals, is an important technique for assessing fetal health. In this work, we develop a robust DUS-based FHR estimation approach complemented by DUS signal quality assessment (SQA) based on unsupervised representation learning in response to the drawbacks of previous DUS-based FHR estimation and DUS SQA methods. We improve the existing FHR estimation algorithm based on the autocorrelation function (ACF), which is the most widely used method for estimating FHR from DUS signals. Short-time Fourier transform (STFT) serves as a signal pre-processing technique that allows the extraction of both temporal and spectral information. In addition, we utilize double ACF calculations, employing the first one to determine an appropriate window size and the second one to estimate the FHR within changing windows. This approach enhances the robustness and adaptability of the algorithm. Furthermore, we tackle the challenge of low-quality signals impacting FHR estimation by introducing a DUS SQA method based on unsupervised representation learning. We employ a variational autoencoder (VAE) to train representations of pre-processed fetal DUS data and aggregate them into a signal quality index (SQI) using a self-organizing map (SOM). By incorporating the SQI and Kalman filter (KF), we refine the estimated FHRs, minimizing errors in the estimation process. Experimental results demonstrate that our proposed approach outperforms conventional methods in terms of accuracy and robustness.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Rate, FetalSignal Processing, Computer-AssistedPregnancyFemaleHumansMonitoring, PhysiologicAlgorithmsUltrasonography, Doppler

Stichwörter der Autor:innen

Doppler ultrasoundautocorrelation functionfetal heart ratesignal quality assessmentunsupervised representation learning

Autor:innen und Institutionen

  • Graduate School of Science and Technology, Keio University, Yokohama 223-8522, Japan.
  • Department of Information and Computer Science, Keio University, Yokohama 223-8522, Japan.
  • Atom Medical Co., Tokyo 113-0021, Japan.

ORCID-Profile: Xintong Shi, Tomoaki Ohtsuki

Förderung

  • Atom Medical Corporation

Zitieren

APA

Shi, X., Niida, N., Yamamoto, K., Ohtsuki, T., Matsui, Y., & Owada, K. (2023). A Robust Approach Assisted by Signal Quality Assessment for Fetal Heart Rate Estimation from Doppler Ultrasound Signal. Sensors. https://doi.org/10.3390/s23249698

Vancouver

Shi X, Niida N, Yamamoto K, Ohtsuki T, Matsui Y, Owada K. A Robust Approach Assisted by Signal Quality Assessment for Fetal Heart Rate Estimation from Doppler Ultrasound Signal. Sensors. 2023. doi:10.3390/s23249698

BibTeX
@article{Shi2023,
  author = {Shi, Xintong and Niida, Natsuho and Yamamoto, Kohei and Ohtsuki, Tomoaki and Matsui, Yutaka and Owada, Kazunari},
  title = {A Robust Approach Assisted by Signal Quality Assessment for Fetal Heart Rate Estimation from Doppler Ultrasound Signal},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23249698}
}
Kostenlos starten →