EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Textile-Based Body Capacitive Sensing for Knee Angle Monitoring

Valeria Galli iD, Chakaveh Ahmadizadeh, Raffael Kunz, Carlo Menon iD

Sensors · 2023

DOI: 10.3390/s23249657 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Valeria Galli und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical and Mobile Health Technology Laboratory, Department of Health Science and Technology, ETH Zurich, Balgrist Campus, Lengghalde 5, 8008 Züri…. Hauptthemen laut MEDLINE: Knee, Wearable Electronic Devices. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Monitoring human movement is highly relevant in mobile health applications. Textile-based wearable solutions have the potential for continuous and unobtrusive monitoring. The precise estimation of joint angles is important in applications such as the prevention of osteoarthritis or in the assessment of the progress of physical rehabilitation. We propose a textile-based wearable device for knee angle estimation through capacitive sensors placed in different locations above the knee and in contact with the skin. We exploited this modality to enhance the baseline value of the capacitive sensors, hence facilitating readout. Moreover, the sensors are fabricated with only one layer of conductive fabric, which facilitates the design and realization of the wearable device. We observed the capability of our system to predict knee sagittal angle in comparison to gold-standard optical motion capture during knee flexion from a seated position and squats: the results showed an R2 coefficient between 0.77 and 0.99, root mean squared errors between 4.15 and 12.19 degrees, and mean absolute errors between 3.28 and 10.34 degrees. Squat movements generally yielded more accurate predictions than knee flexion from a seated position. The combination of the data from multiple sensors resulted in R2 coefficient values of 0.88 or higher. This preliminary work demonstrates the feasibility of the presented system. Future work should include more participants to further assess the accuracy and repeatability in the presence of larger interpersonal variability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KneeWearable Electronic DevicesHumansKnee JointMovementTextiles

Stichwörter der Autor:innen

motion capturesmart clothingstrain sensortextile sensorwearable technology

Autor:innen und Institutionen

  • Biomedical and Mobile Health Technology Laboratory, Department of Health Science and Technology, ETH Zurich, Balgrist Campus, Lengghalde 5, 8008 Zürich, Switzerland.
  • Department of Mechanical and Process Engineering, ETH Zurich, 8092 Zürich, Switzerland.

ORCID-Profile: Valeria Galli, Carlo Menon

Zitieren

APA

Galli, V., Ahmadizadeh, C., Kunz, R., & Menon, C. (2023). Textile-Based Body Capacitive Sensing for Knee Angle Monitoring. Sensors. https://doi.org/10.3390/s23249657

Vancouver

Galli V, Ahmadizadeh C, Kunz R, Menon C. Textile-Based Body Capacitive Sensing for Knee Angle Monitoring. Sensors. 2023. doi:10.3390/s23249657

BibTeX
@article{Galli2023,
  author = {Galli, Valeria and Ahmadizadeh, Chakaveh and Kunz, Raffael and Menon, Carlo},
  title = {Textile-Based Body Capacitive Sensing for Knee Angle Monitoring},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23249657}
}
Kostenlos starten →