A Multi-Layer Classifier Model XR-KS of Human Activity Recognition for the Problem of Similar Human Activity
Sensors · 2023
DOI: 10.3390/s23239613 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Qiancheng Tan und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Mathematics and Computing Science, Guangxi Colleges and Universities Key Laboratory of Data Analysis and Computation, Guilin University of…. Hauptthemen laut MEDLINE: Algorithms, Human Activities. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Guangxi Key Laboratory of Automatic Detecting Technology and Instruments, Innovation and Entrepreneurship Training Program for College Students of Guangxi.
Abstract (Originalsprache)
Sensor-based human activity recognition is now well developed, but there are still many challenges, such as insufficient accuracy in the identification of similar activities. To overcome this issue, we collect data during similar human activities using three-axis acceleration and gyroscope sensors. We developed a model capable of classifying similar activities of human behavior, and the effectiveness and generalization capabilities of this model are evaluated. Based on the standardization and normalization of data, we consider the inherent similarities of human activity behaviors by introducing the multi-layer classifier model. The first layer of the proposed model is a random forest model based on the XGBoost feature selection algorithm. In the second layer of this model, similar human activities are extracted by applying the kernel Fisher discriminant analysis (KFDA) with feature mapping. Then, the support vector machine (SVM) model is applied to classify similar human activities. Our model is experimentally evaluated, and it is also applied to four benchmark datasets: UCI DSA, UCI HAR, WISDM, and IM-WSHA. The experimental results demonstrate that the proposed approach achieves recognition accuracies of 97.69%, 97.92%, 98.12%, and 90.6%, indicating excellent recognition performance. Additionally, we performed K-fold cross-validation on the random forest model and utilized ROC curves for the SVM classifier to assess the model’s generalization ability. The results indicate that our multi-layer classifier model exhibits robust generalization capabilities.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Mathematics and Computing Science, Guangxi Colleges and Universities Key Laboratory of Data Analysis and Computation, Guilin University of Electronic Technology, Guilin 541004, China.
- Center for Applied Mathematics of Guangxi (GUET), Guilin 541004, China.
- Guangxi Key Laboratory of Automatic Detecting Technology and Instruments, Guilin University of Electronic Technology, Guilin 541004, China.
- School of Advanced Manufacturing, Fuzhou University, Fuzhou 350108, China.
- College of Electrical Engineering and Information, Northeast Agricultural University, Harbin 150030, China.
ORCID-Profile: Qiancheng Tan, Yonghui Qin, Rui Tang, Sixuan Wu, Jing Cao
Förderung
- National Natural Science Foundation of China
- Guangxi Key Laboratory of Automatic Detecting Technology and Instruments
- Innovation and Entrepreneurship Training Program for College Students of Guangxi
Zitieren
APA
Tan, Q., Qin, Y., Tang, R., Wu, S., & Cao, J. (2023). A Multi-Layer Classifier Model XR-KS of Human Activity Recognition for the Problem of Similar Human Activity. Sensors. https://doi.org/10.3390/s23239613
Vancouver
Tan Q, Qin Y, Tang R, Wu S, Cao J. A Multi-Layer Classifier Model XR-KS of Human Activity Recognition for the Problem of Similar Human Activity. Sensors. 2023. doi:10.3390/s23239613
BibTeX
@article{Tan2023,
author = {Tan, Qiancheng and Qin, Yonghui and Tang, Rui and Wu, Sixuan and Cao, Jing},
title = {A Multi-Layer Classifier Model XR-KS of Human Activity Recognition for the Problem of Similar Human Activity},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23239613}
}
EUVIMED