EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A New Method to Evaluate Pressure Distribution Using a 3D-Printed C2-C3 Cervical Spine Model with an Embedded Sensor Array

Maohua Lin iD, Rudy Paul iD, Xinqin Liao iD, James Doulgeris, Emma Lilly Menzer, Utpal Kanti Dhar iD, Chi-Tay Tsai iD, Frank D Vrionis iD

Sensors · 2023

DOI: 10.3390/s23239547 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Maohua Lin und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, FL 33431, USA. Hauptthemen laut MEDLINE: Spinal Fusion, Intervertebral Disc Degeneration. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Boca Raton Regional Hospital Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cervical degenerative disc diseases such as myelopathy and radiculopathy often require conventional treatments like artificial cervical disc replacement or anterior cervical discectomy and fusion (ACDF). When designing a medical device, like the stand-alone cage, there are many design inputs to consider. However, the precise biomechanics of the force between the vertebrae and implanted devices under certain conditions require further investigation. In this study, a new method was developed to evaluate the pressure between the vertebrae and implanted devices by embedding a sensor array into a 3D-printed C2-C3 cervical spine. The 3D-printed cervical spine model was subjected to a range of axial loads while under flexion, extension, bending and compression conditions. Cables were used for the application of a preload and a robotic arm was used to recreate the natural spine motions (flexion, extension, and bending). To verify and predict the total pressure between the vertebrae and the implanted devices, a 3D finite element (FE) numerical mathematical model was developed. A preload was represented by applying 22 N of force on each of the anterior tubercles for the C2 vertebra. The results of this study suggest that the sensor is useful in identifying static pressure. The pressure with the robot arm was verified from the FE results under all conditions. This study indicates that the sensor array has promising potential to reduce the trial and error with implants for various surgical procedures, including multi-level artificial cervical disk replacement and ACDF, which may help clinicians to reduce pain, suffering, and costly follow-up procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spinal FusionIntervertebral Disc DegenerationHumansCervical VertebraeDiskectomyBiomechanical PhenomenaRange of Motion, ArticularPrinting, Three-Dimensional

Stichwörter der Autor:innen

3D printACDFcervical spinefinite element analysissensor array

Autor:innen und Institutionen

  • Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, FL 33431, USA.
  • Department of Electronic Science, Xiamen University, Xiamen 361005, China.
  • Department of Biological Sciences, Florida Atlantic University, Boca Raton, FL 33431, USA.
  • Department of Neurosurgery, Marcus Neuroscience Institute, Boca Raton Regional Hospital, Boca Raton, FL 33486, USA.

ORCID-Profile: Maohua Lin, Rudy Paul, Xinqin Liao, Utpal Kanti Dhar, Chi-Tay Tsai, Frank D Vrionis

Förderung

  • Boca Raton Regional Hospital Foundation

Zitieren

APA

Lin, M., Paul, R., Liao, X., Doulgeris, J., Menzer, E. L., Dhar, U. K., Tsai, C. T., & Vrionis, F. D. (2023). A New Method to Evaluate Pressure Distribution Using a 3D-Printed C2-C3 Cervical Spine Model with an Embedded Sensor Array. Sensors. https://doi.org/10.3390/s23239547

Vancouver

Lin M, Paul R, Liao X, Doulgeris J, Menzer EL, Dhar UK, et al. A New Method to Evaluate Pressure Distribution Using a 3D-Printed C2-C3 Cervical Spine Model with an Embedded Sensor Array. Sensors. 2023. doi:10.3390/s23239547

BibTeX
@article{Lin2023,
  author = {Lin, Maohua and Paul, Rudy and Liao, Xinqin and Doulgeris, James and Menzer, Emma Lilly and Dhar, Utpal Kanti and Tsai, Chi-Tay and Vrionis, Frank D},
  title = {A New Method to Evaluate Pressure Distribution Using a 3D-Printed C2-C3 Cervical Spine Model with an Embedded Sensor Array},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23239547}
}
Kostenlos starten →