InAsSb Photodiode Fibre Optic Thermometry for High-Speed, near-Ambient Temperature Measurements
Sensors · 30.11.2023 · 23 (23) · 9514
DOI: 10.3390/s23239514 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 30.11.2023. Verfasst von Emilios Leonidas und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Material Science & Engineering, University of Sheffield, Sheffield S1 3JD, UK. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science Foundation Ireland, Advanced Manufacturing Research Centre (AMRC), Advanced Forming Research Centre (AFRC).
Abstract (Originalsprache)
Infrared radiation thermometers (IRTs) overcome many of the limitations of thermocouples, particularly responsiveness and calibration drift. The main challenge with radiation thermometry is the fast and reliable measurement of temperatures close to room temperature. A new IRT which is sensitive to wavelengths between 3 μm and 11 μm was developed and tested in a laboratory setting. It is based on an uncooled indium arsenide antimony (InAsSb) photodiode, a transimpedance amplifier, and a silver halogenide fibre optic cable transmissive in the mid- to long-wave infrared region. The prototype IRT was capable of measuring temperatures between 35 °C and 100 °C at an integration time of 5 ms and a temperature range between 40 °C and 100 °C at an integration time of 1 ms, with a root mean square (RMS) noise level of less than 0.5 °C. The thermometer was calibrated against Planck’s law using a five-point calibration, leading to a measurement uncertainty within ±1.5 °C over the aforementioned temperature range. The thermometer was tested against a thermocouple during drilling operations of polyether ether ketone (PEEK) plastic to measure the temperature of the drill bit during the material removal process. Future versions of the thermometer are intended to be used as a thermocouple replacement in high-speed, near-ambient temperature measurement applications, such as electric motor condition monitoring; battery protection; and machining of polymers and composite materials, such as carbon-fibre-reinforced plastic (CFRP).
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Material Science & Engineering, University of Sheffield, Sheffield S1 3JD, UK.
- Sensor Systems Group, Department of Electrical & Electronic Engineering, University of Sheffield, Sheffield S1 4ET, UK.
- Advanced Manufacturing Research Centre (AMRC), Machining Research, Process Modelling & Control Group Centre, Factory of the Future, Rotherham S60 5TZ, UK.
- Advanced Forming Research Centre (AFRC), Paisley PA4 9LJ, UK.
ORCID-Profile: Emilios Leonidas, Matthew J Hobbs, Jon R Willmott
Förderung
- Science Foundation Ireland
- Advanced Manufacturing Research Centre (AMRC)
- Advanced Forming Research Centre (AFRC)
- Engineering and Physical Sciences Research Council UK
Zitieren
APA
Leonidas, E., Hobbs, M. J., Ayvar-Soberanis, S., Laalej, H., Fisk, C., Fitzpatrick, S., & Willmott, J. R. (2023). InAsSb Photodiode Fibre Optic Thermometry for High-Speed, near-Ambient Temperature Measurements. Sensors, 23(23), 9514. https://doi.org/10.3390/s23239514
Vancouver
Leonidas E, Hobbs MJ, Ayvar-Soberanis S, Laalej H, Fisk C, Fitzpatrick S, et al. InAsSb Photodiode Fibre Optic Thermometry for High-Speed, near-Ambient Temperature Measurements. Sensors. 2023;23(23):9514. doi:10.3390/s23239514
BibTeX
@article{Leonidas2023,
author = {Leonidas, Emilios and Hobbs, Matthew J and Ayvar-Soberanis, Sabino and Laalej, Hatim and Fisk, Callum and Fitzpatrick, Stephen and Willmott, Jon R},
title = {InAsSb Photodiode Fibre Optic Thermometry for High-Speed, near-Ambient Temperature Measurements},
journal = {Sensors},
year = {2023},
volume = {23},
number = {23},
pages = {9514},
doi = {10.3390/s23239514}
}
EUVIMED