EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Validity and Efficacy of the Elite HRV Smartphone Application during Slow-Paced Breathing

Joseph D Vondrasek, Bryan L Riemann iD, Gregory J Grosicki iD, Andrew A Flatt iD

Sensors · 2023

DOI: 10.3390/s23239496 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Joseph D Vondrasek und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biodynamics and Human Performance Center, Department of Health Sciences and Kinesiology, Georgia Southern University (Armstrong), 11935 Abercorn St.,…. Hauptthemen laut MEDLINE: Smartphone, Mobile Applications. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Slow-paced breathing is a clinical intervention used to increase heart rate variability (HRV). The practice is made more accessible via cost-free smartphone applications like Elite HRV. We investigated whether Elite HRV can accurately measure and augment HRV via its slow-paced breathing feature. Twenty young adults completed one counterbalanced cross-over protocol involving 10 min each of supine spontaneous (SPONT) and paced (PACED; 6 breaths·min−1) breathing while RR intervals were simultaneously recorded via a Polar H10 paired with Elite HRV and reference electrocardiography (ECG). Individual differences in HRV between devices were predominately skewed, reflecting a tendency for Elite HRV to underestimate ECG-derived values. Skewness was typically driven by a limited number of outliers as median bias values were ≤1.3 ms and relative agreement was ≥very large for time-domain parameters. Despite no significant bias and ≥large relative agreement for frequency-domain parameters, limits of agreement (LOAs) were excessively wide and tended to be wider during PACED for all HRV parameters. PACED significantly increased low-frequency power (LF) for Elite HRV and ECG, and between-condition differences showed very large relative agreement. Elite HRV-guided slow-paced breathing effectively increased LF values, but it demonstrated greater precision during SPONT and in computing time-domain HRV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SmartphoneMobile ApplicationsYoung AdultHumansHeart RateRespiratory RateRespirationElectrocardiography

Stichwörter der Autor:innen

autonomicbiofeedbackheart rate variabilityparasympatheticpsychophysiology

Autor:innen und Institutionen

  • Biodynamics and Human Performance Center, Department of Health Sciences and Kinesiology, Georgia Southern University (Armstrong), 11935 Abercorn St., Savannah, GA 31419, USA.

ORCID-Profile: Bryan L Riemann, Gregory J Grosicki, Andrew A Flatt

Zitieren

APA

Vondrasek, J. D., Riemann, B. L., Grosicki, G. J., & Flatt, A. A. (2023). Validity and Efficacy of the Elite HRV Smartphone Application during Slow-Paced Breathing. Sensors. https://doi.org/10.3390/s23239496

Vancouver

Vondrasek JD, Riemann BL, Grosicki GJ, Flatt AA. Validity and Efficacy of the Elite HRV Smartphone Application during Slow-Paced Breathing. Sensors. 2023. doi:10.3390/s23239496

BibTeX
@article{Vondrasek2023,
  author = {Vondrasek, Joseph D and Riemann, Bryan L and Grosicki, Gregory J and Flatt, Andrew A},
  title = {Validity and Efficacy of the Elite HRV Smartphone Application during Slow-Paced Breathing},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23239496}
}