A Reliable Pipeline Leak Detection Method Using Acoustic Emission with Time Difference of Arrival and Kolmogorov–Smirnov Test

Duc-Thuan Nguyen iD, Tuan-Khai Nguyen iD, Zahoor Ahmad iD, Jong-Myon Kim iD

Sensors · 21.11.2023 · 23 (23) · 9296

DOI: 10.3390/s23239296 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 21.11.2023. Verfasst von Duc-Thuan Nguyen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical, Electronic and Computer Engineering, University of Ulsan, Ulsan 44610, Republic of Korea. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Trade, Industry and Energy, Ministry of Education and National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper proposes a novel and reliable leak-detection method for pipeline systems based on acoustic emission (AE) signals. The proposed method analyzes signals from two AE sensors installed on the pipeline to detect leaks located between these two sensors. Firstly, the raw AE signals are preprocessed using empirical mode decomposition. The time difference of arrival (TDOA) is then extracted as a statistical feature of the two AE signals. The state of the pipeline (leakage/normal) is determined through comparing the statistical distribution of the TDOA of the current state with the prior normal state. Specifically, the two-sample Kolmogorov–Smirnov (K–S) test is applied to compare the statistical distribution of the TDOA feature for leak and non-leak scenarios. The K–S test statistic value in this context functions as a leakage indicator. A new criterion called leak sensitivity is introduced to evaluate and compare the performance of leak detection methods. Extensive experiments were conducted using an industrial pipeline system, and the results demonstrate the excellence of the proposed method in leak detection. Compared to traditional feature-based indicators, our approach achieves a significantly higher performance in leak detection.

Schlagwörter

Stichwörter der Autor:innen

Kolmogorov–Smirnov testacoustic emissioncross-correlationleak detectionpipeline systemstime difference of arrival

Autor:innen und Institutionen

  • Department of Electrical, Electronic and Computer Engineering, University of Ulsan, Ulsan 44610, Republic of Korea.
  • PD Technology Co., Ltd., Ulsan 44610, Republic of Korea.

ORCID-Profile: Duc-Thuan Nguyen, Tuan-Khai Nguyen, Zahoor Ahmad, Jong-Myon Kim

Förderung

  • Ministry of Trade, Industry and Energy
  • Ministry of Education and National Research Foundation of Korea

Zitieren

APA

Nguyen, D. T., Nguyen, T. K., Ahmad, Z., & Kim, J. M. (2023). A Reliable Pipeline Leak Detection Method Using Acoustic Emission with Time Difference of Arrival and Kolmogorov–Smirnov Test. Sensors, 23(23), 9296. https://doi.org/10.3390/s23239296

Vancouver

Nguyen DT, Nguyen TK, Ahmad Z, Kim JM. A Reliable Pipeline Leak Detection Method Using Acoustic Emission with Time Difference of Arrival and Kolmogorov–Smirnov Test. Sensors. 2023;23(23):9296. doi:10.3390/s23239296

BibTeX
@article{Nguyen2023,
  author = {Nguyen, Duc-Thuan and Nguyen, Tuan-Khai and Ahmad, Zahoor and Kim, Jong-Myon},
  title = {A Reliable Pipeline Leak Detection Method Using Acoustic Emission with Time Difference of Arrival and Kolmogorov–Smirnov Test},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {23},
  pages = {9296},
  doi = {10.3390/s23239296}
}
Kostenlos starten →