Assessment of an IMU-Based Experimental Set-Up for Upper Limb Motion in Obese Subjects
Sensors · 18.11.2023 · 23 (22) · 9264
DOI: 10.3390/s23229264 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 18.11.2023. Verfasst von Serena Cerfoglio und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy. Hauptthemen laut MEDLINE: Upper Extremity, Shoulder. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Italian Ministry of Health.
Abstract (Originalsprache)
In recent years, wearable systems based on inertial sensors opened new perspectives for functional motor assessment with respect to the gold standard motion capture systems. The aim of this study was to validate an experimental set-up based on 17 body-worn inertial sensors (Awinda, Xsens, The Netherlands), addressing specific body segments with respect to the state-of-the art system (VICON, Oxford Metrics Ltd., Oxford, UK) to assess upper limb kinematics in obese, with respect to healthy subjects. Twenty-three obese and thirty healthy weight individuals were simultaneously acquainted with the two systems across a set of three tasks for upper limbs (i.e., frontal arm rise, lateral arm rise, and reaching). Root Mean Square error (RMSE) was computed to quantify the differences between the measurements provided by the systems in terms of range of motion (ROM), whilst their agreement was assessed via Pearson’s correlation coefficient (PCC) and Bland–Altman (BA) plots. In addition, the signal waveforms were compared via one-dimensional statistical parametrical mapping (SPM) based on a paired t-test and a two-way ANOVA was applied on ROMs. The overall results partially confirmed the correlation and the agreement between the two systems, reporting only a moderate correlation for shoulder principal rotation angle in each task (r~0.40) and for elbow/flexion extension in obese subjects (r = 0.66), whilst no correlation was found for most non-principal rotation angles (r < 0.40). Across the performed tasks, an average RMSE of 34° and 26° was reported in obese and healthy controls, respectively. At the current state, the presence of bias limits the applicability of the inertial-based system in clinics; further research is intended in this context.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy.
- Orthopaedic Rehabilitation Unit and Research Laboratory in Biomechanics, Rehabilitation and Ergonomics, San Giuseppe Hospital, IRCCS Istituto Auxologico Italiano, 28824 Piancavallo, Italy.
- Dipartimento di Ingegneria dell'Informazione, Università degli Studi di Brescia, 25123 Brescia, Italy.
- Department of Surgical Sciences, Physical Medicine and Rehabilitation, University of Turin, 10126 Turin, Italy.
- Dipartimento di Specialità Medico-Chirurgiche, Scienze Radiologiche e Sanità Pubblica, Università degli Studi di Brescia, 25123 Brescia, Italy.
ORCID-Profile: Serena Cerfoglio, Nicola Francesco Lopomo, Paolo Capodaglio, Emilia Scalona, Riccardo Monfrini, Federica Verme, Manuela Galli, Veronica Cimolin
Förderung
- Italian Ministry of Health
Zitieren
APA
Cerfoglio, S., Lopomo, N. F., Capodaglio, P., Scalona, E., Monfrini, R., Verme, F., Galli, M., & Cimolin, V. (2023). Assessment of an IMU-Based Experimental Set-Up for Upper Limb Motion in Obese Subjects. Sensors, 23(22), 9264. https://doi.org/10.3390/s23229264
Vancouver
Cerfoglio S, Lopomo NF, Capodaglio P, Scalona E, Monfrini R, Verme F, et al. Assessment of an IMU-Based Experimental Set-Up for Upper Limb Motion in Obese Subjects. Sensors. 2023;23(22):9264. doi:10.3390/s23229264
BibTeX
@article{Cerfoglio2023,
author = {Cerfoglio, Serena and Lopomo, Nicola Francesco and Capodaglio, Paolo and Scalona, Emilia and Monfrini, Riccardo and Verme, Federica and Galli, Manuela and Cimolin, Veronica},
title = {Assessment of an IMU-Based Experimental Set-Up for Upper Limb Motion in Obese Subjects},
journal = {Sensors},
year = {2023},
volume = {23},
number = {22},
pages = {9264},
doi = {10.3390/s23229264}
}
EUVIMED