Stereoselective Voltammetric Biosensor for Myo-Inositol and D-Chiro-Inositol Recognition
Sensors · 2023
DOI: 10.3390/s23229211 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Cristina Tortolini und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Experimental Medicine, Sapienza University of Rome, Viale Regina Elena 324, 00161 Rome, Italy. Hauptthemen laut MEDLINE: Inositol, Methylene Blue. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This paper describes the development of a simple voltammetric biosensor for the stereoselective discrimination of myo-inositol (myo-Ins) and D-chiro-inositol (D-chiro-Ins) by means of bovine serum albumin (BSA) adsorption onto a multi-walled carbon nanotube (MWCNT) graphite screen-printed electrode (MWCNT-GSPE), previously functionalized by the electropolymerization of methylene blue (MB). After a morphological characterization, the enantioselective biosensor platform was electrochemically characterized after each modification step by differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The results show that the binding affinity between myo-Ins and BSA was higher than that between D-chiro-Ins and BSA, confirming the different interactions exhibited by the novel BSA/MB/MWCNT/GSPE platform towards the two diastereoisomers. The biosensor showed a linear response towards both stereoisomers in the range of 2–100 μM, with LODs of 0.5 and 1 μM for myo-Ins and D-chiro-Ins, respectively. Moreover, a stereoselectivity coefficient α of 1.6 was found, with association constants of 0.90 and 0.79, for the two stereoisomers, respectively. Lastly, the proposed biosensor allowed for the determination of the stereoisomeric composition of myo-/D-chiro-Ins mixtures in commercial pharmaceutical preparations, and thus, it is expected to be successfully applied in the chiral analysis of pharmaceuticals and illicit drugs of forensic interest.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Experimental Medicine, Sapienza University of Rome, Viale Regina Elena 324, 00161 Rome, Italy.
- Department of Chemistry and Drug Technologies, Sapienza University of Rome, Piazzale Aldo Moro 5, 00185 Rome, Italy.
ORCID-Profile: Cristina Tortolini, Valeria Gigli, Flavio Rizzo, Mariano Bizzarri, Riccarda Antiochia
Zitieren
APA
Tortolini, C., Gigli, V., Rizzo, F., Lenzi, A., Bizzarri, M., Angeloni, A., & Antiochia, R. (2023). Stereoselective Voltammetric Biosensor for Myo-Inositol and D-Chiro-Inositol Recognition. Sensors. https://doi.org/10.3390/s23229211
Vancouver
Tortolini C, Gigli V, Rizzo F, Lenzi A, Bizzarri M, Angeloni A, et al. Stereoselective Voltammetric Biosensor for Myo-Inositol and D-Chiro-Inositol Recognition. Sensors. 2023. doi:10.3390/s23229211
BibTeX
@article{Tortolini2023,
author = {Tortolini, Cristina and Gigli, Valeria and Rizzo, Flavio and Lenzi, Andrea and Bizzarri, Mariano and Angeloni, Antonio and Antiochia, Riccarda},
title = {Stereoselective Voltammetric Biosensor for Myo-Inositol and D-Chiro-Inositol Recognition},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23229211}
}
EUVIMED