EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Stress Level Detection Based on the Capacitive Electrocardiogram Signals of Driving Subjects

Tamara Škorić iD

Sensors · 14.11.2023 · 23 (22) · 9158

DOI: 10.3390/s23229158 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 14.11.2023. Verfasst von Tamara Škorić. Beteiligte Einrichtung: Faculty of Technical Science, University of Novi Sad, 21000 Novi Sad, Serbia. Hauptthemen laut MEDLINE: Electrocardiography. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Serbian Ministry of Education, Science and Technology Development, Centre for Vibro-Acoustic Systems and Signal Processing (CEVAS).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The automotive industry and scientific community are making efforts to develop innovative solutions that would increase successful driver performance in preventing crashes caused by drivers’ health and concentration. High stress is one of the causes of impaired driver performance. This study investigates the ability to classify different stress levels based on capacitive electrocardiogram (cECG) recorded during driving by unobtrusive acquisition systems with different hardware implementations. The proposed machine-learning model extracted only four features, based on the detection of the R peak, which is the most reliably detected characteristic point even in inferior quality cECG. Another criterion for selecting the features is their low computational complexity, which enables real-time application. The proposed method was validated on three open data sets recorded during driving: electrocardiogram (ECG) recorded by electrodes with direct skin contact (high quality); cECG recorded without direct skin contact through clothes by electrodes built into a portable multi-modal cushion (middle quality); and cECG recorded through the clothes without direct skin contact by electrodes built into a car seat (lowest quality). The proposed model achieved a high accuracy of 100% for high-quality ECG, 96.67% for middle-quality cECG, and 98.08% for the lower-quality cECG.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocardiographyHumansElectrodes

Stichwörter der Autor:innen

cECG filtermachine-learning model for stress level detectionunobtrusive health monitoring system

Autor:innen und Institutionen

  • Faculty of Technical Science, University of Novi Sad, 21000 Novi Sad, Serbia.

ORCID-Profile: Tamara Škorić

Förderung

  • Serbian Ministry of Education, Science and Technology Development
  • Centre for Vibro-Acoustic Systems and Signal Processing (CEVAS)

Zitieren

APA

Škorić, T. (2023). Stress Level Detection Based on the Capacitive Electrocardiogram Signals of Driving Subjects. Sensors, 23(22), 9158. https://doi.org/10.3390/s23229158

Vancouver

Škorić T. Stress Level Detection Based on the Capacitive Electrocardiogram Signals of Driving Subjects. Sensors. 2023;23(22):9158. doi:10.3390/s23229158

BibTeX
@article{kori2023,
  author = {Škorić, Tamara},
  title = {Stress Level Detection Based on the Capacitive Electrocardiogram Signals of Driving Subjects},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {22},
  pages = {9158},
  doi = {10.3390/s23229158}
}
Kostenlos starten →