EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Minimum Detection Concentration of Hydrogen in Air Depending on Substrate Type and Design of the 3ω Sensor

Dong-Wook Oh iD, Kwangu Kang iD, Jung-Hee Lee

Sensors · 06.11.2023 · 23 (21) · 9009

DOI: 10.3390/s23219009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 06.11.2023. Verfasst von Dong-Wook Oh und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Chosun University, Gwangju 61452, Republic of Korea. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIEHS NIH HHS, Korea Research Institute of Ships & Ocean Engineering, Ministry of Oceans and Fisheries.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hydrogen has emerged as a promising carbon-neutral fuel source, spurring research and development efforts to facilitate its widespread adoption. However, the safe handling of hydrogen requires precise leak detection sensors due to its low activation energy and explosive potential. Various detection methods exist, with thermal conductivity measurement being a prominent technique for quantifying hydrogen concentrations. However, challenges remain in achieving high measurement sensitivity at low hydrogen concentrations below 1% for thermal-conductivity-based hydrogen sensors. Recent research explores the 3ω method’s application for measuring hydrogen concentrations in ambient air, offering high spatial and temporal resolutions. This study aims to enhance hydrogen leak detection sensitivity using the 3ω method by conducting thermal analyses on sensor design variables. Factors including substrate material, type, and sensor geometry significantly impact the measurement sensitivity. Comparative evaluations consider the minimum detectable hydrogen concentration while accounting for the uncertainty of the 3ω signal. The proposed suspended-type 3ω sensor is capable of detecting hydrogen leaks in ambient air and provides real-time measurements that are ideal for monitoring hydrogen diffusion. This research serves to bridge the gap between precision and real-time monitoring of hydrogen leak detection, promising significant advancements in the related safety applications.

Schlagwörter

Stichwörter der Autor:innen

3 omega methodgas thermal conductivityhydrogen concentrationminimum detection concentration

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Chosun University, Gwangju 61452, Republic of Korea.
  • Offshore Industries R&BD Center, Korea Research Institute of Ships & Ocean Engineering, Geoje 53201, Republic of Korea.

ORCID-Profile: Dong-Wook Oh, Kwangu Kang

Förderung

  • NIEHS NIH HHS
  • Korea Research Institute of Ships & Ocean Engineering
  • Ministry of Oceans and Fisheries

Zitieren

APA

Oh, D. W., Kang, K., & Lee, J. H. (2023). Minimum Detection Concentration of Hydrogen in Air Depending on Substrate Type and Design of the 3ω Sensor. Sensors, 23(21), 9009. https://doi.org/10.3390/s23219009

Vancouver

Oh DW, Kang K, Lee JH. Minimum Detection Concentration of Hydrogen in Air Depending on Substrate Type and Design of the 3ω Sensor. Sensors. 2023;23(21):9009. doi:10.3390/s23219009

BibTeX
@article{Oh2023,
  author = {Oh, Dong-Wook and Kang, Kwangu and Lee, Jung-Hee},
  title = {Minimum Detection Concentration of Hydrogen in Air Depending on Substrate Type and Design of the 3ω Sensor},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {21},
  pages = {9009},
  doi = {10.3390/s23219009}
}
Kostenlos starten →