A Convolutional Neural Network for Beamforming and Image Reconstruction in Passive Cavitation Imaging
Sensors · 27.10.2023 · 23 (21) · 8760
DOI: 10.3390/s23218760 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 27.10.2023. Verfasst von Hossein J Sharahi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada. Hauptthemen laut MEDLINE: Percutaneous Coronary Intervention. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: INOVAIT (funding from the SIF program from the government of Canada), Arrayus technologies, Temerty Chair in Focused Ultrasound Research at Sunnybrook Health Sciences Centre.
Abstract (Originalsprache)
Convolutional neural networks (CNNs), initially developed for image processing applications, have recently received significant attention within the field of medical ultrasound imaging. In this study, passive cavitation imaging/mapping (PCI/PAM), which is used to map cavitation sources based on the correlation of signals across an array of receivers, is evaluated. Traditional reconstruction techniques in PCI, such as delay-and-sum, yield high spatial resolution at the cost of a substantial computational time. This results from the resource-intensive process of determining sensor weights for individual pixels in these methodologies. Consequently, the use of conventional algorithms for image reconstruction does not meet the speed requirements that are essential for real-time monitoring. Here, we show that a three-dimensional (3D) convolutional network can learn the image reconstruction algorithm for a 16×16 element matrix probe with a receive frequency ranging from 256 kHz up to 1.0 MHz. The network was trained and evaluated using simulated data representing point sources, resulting in the successful reconstruction of volumetric images with high sensitivity, especially for single isolated sources (100% in the test set). As the number of simultaneous sources increased, the network’s ability to detect weaker intensity sources diminished, although it always correctly identified the main lobe. Notably, however, network inference was remarkably fast, completing the task in approximately 178 s for a dataset comprising 650 frames of 413 volume images with signal duration of 20μs. This processing speed is roughly thirty times faster than a parallelized implementation of the traditional time exposure acoustics algorithm on the same GPU device. This would open a new door for PCI application in the real-time monitoring of ultrasound ablation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada.
- Department of Medical Biophysics, University of Toronto, Toronto, ON M5G 1L7, Canada.
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada.
ORCID-Profile: Hossein J Sharahi, Kullervo Hynynen
Förderung
- INOVAIT (funding from the SIF program from the government of Canada)
- Arrayus technologies
- Temerty Chair in Focused Ultrasound Research at Sunnybrook Health Sciences Centre
Zitieren
APA
Sharahi, H. J., Acconcia, C. N., Li, M., Martel, A., & Hynynen, K. (2023). A Convolutional Neural Network for Beamforming and Image Reconstruction in Passive Cavitation Imaging. Sensors, 23(21), 8760. https://doi.org/10.3390/s23218760
Vancouver
Sharahi HJ, Acconcia CN, Li M, Martel A, Hynynen K. A Convolutional Neural Network for Beamforming and Image Reconstruction in Passive Cavitation Imaging. Sensors. 2023;23(21):8760. doi:10.3390/s23218760
BibTeX
@article{Sharahi2023,
author = {Sharahi, Hossein J and Acconcia, Christopher N and Li, Matthew and Martel, Anne and Hynynen, Kullervo},
title = {A Convolutional Neural Network for Beamforming and Image Reconstruction in Passive Cavitation Imaging},
journal = {Sensors},
year = {2023},
volume = {23},
number = {21},
pages = {8760},
doi = {10.3390/s23218760}
}
EUVIMED