Is Running Power a Useful Metric? Quantifying Training Intensity and Aerobic Fitness Using Stryd Running Power Near the Maximal Lactate Steady State
Sensors · 26.10.2023 · 23 (21) · 8729
DOI: 10.3390/s23218729 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 26.10.2023. Verfasst von Cody R van Rassel und 6 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 1N4, Canada. Hauptthemen laut MEDLINE: Lactic Acid, Running. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council, University of Calgary, Faculty of Kinesiology (University of Calgary).
Abstract (Originalsprache)
We sought to determine the utility of Stryd, a commercially available inertial measurement unit, to quantify running intensity and aerobic fitness. Fifteen (eight male, seven female) runners (age = 30.2 [4.3] years; V·O2max = 54.5 [6.5] ml·kg−1·min−1) performed moderate- and heavy-intensity step transitions, an incremental exercise test, and constant-speed running trials to establish the maximal lactate steady state (MLSS). Stryd running power stability, sensitivity, and reliability were evaluated near the MLSS. Stryd running power was also compared to running speed, V·O2, and metabolic power measures to estimate running mechanical efficiency (EFF) and to determine the efficacy of using Stryd to delineate exercise intensities, quantify aerobic fitness, and estimate running economy (RE). Stryd running power was strongly associated with V·O2 (R2 = 0.84; p < 0.001) and running speed at the MLSS (R2 = 0.91; p < 0.001). Stryd running power measures were strongly correlated with RE at the MLSS when combined with metabolic data (R2 = 0.79; p < 0.001) but not in isolation from the metabolic data (R2 = 0.08; p = 0.313). Measures of running EFF near the MLSS were not different across intensities (~21%; p > 0.05). In conclusion, although Stryd could not quantify RE in isolation, it provided a stable, sensitive, and reliable metric that can estimate aerobic fitness, delineate exercise intensities, and approximate the metabolic requirements of running near the MLSS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 1N4, Canada.
- Department of Health and Physical Education, Mount Royal University, Calgary, AB T3E 6K6, Canada.
ORCID-Profile: Cody R van Rassel, Oluwatimilehin O Ajayi, Jared R Fletcher
Förderung
- Natural Sciences and Engineering Research Council
- University of Calgary
- Faculty of Kinesiology (University of Calgary)
- NSERC CREATE We-TRAC
Zitieren
APA
van Rassel, C. R., Ajayi, O. O., Sales, K. M., Griffiths, J. K., Fletcher, J. R., Edwards, W. B., & MacInnis, M. J. (2023). Is Running Power a Useful Metric? Quantifying Training Intensity and Aerobic Fitness Using Stryd Running Power Near the Maximal Lactate Steady State. Sensors, 23(21), 8729. https://doi.org/10.3390/s23218729
Vancouver
van Rassel CR, Ajayi OO, Sales KM, Griffiths JK, Fletcher JR, Edwards WB, et al. Is Running Power a Useful Metric? Quantifying Training Intensity and Aerobic Fitness Using Stryd Running Power Near the Maximal Lactate Steady State. Sensors. 2023;23(21):8729. doi:10.3390/s23218729
BibTeX
@article{vanRassel2023,
author = {van Rassel, Cody R and Ajayi, Oluwatimilehin O and Sales, Kate M and Griffiths, James K and Fletcher, Jared R and Edwards, W Brent and MacInnis, Martin J},
title = {Is Running Power a Useful Metric? Quantifying Training Intensity and Aerobic Fitness Using Stryd Running Power Near the Maximal Lactate Steady State},
journal = {Sensors},
year = {2023},
volume = {23},
number = {21},
pages = {8729},
doi = {10.3390/s23218729}
}
EUVIMED