Cranial Electrode Belt Position Improves Diagnostic Possibilities of Electrical Impedance Tomography during Laparoscopic Surgery with Capnoperitoneum
Sensors · 2023
DOI: 10.3390/s23208644 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Kristyna Koldova und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 272 01 Kladno, Czech Republic. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Laparoscopy. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Czech Technical University in Prague.
Abstract (Originalsprache)
Laparoscopic surgery with capnoperitoneum brings many advantages to patients, but also emphasizes the negative impact of anesthesia and mechanical ventilation on the lungs. Even though many studies use electrical impedance tomography (EIT) for lung monitoring during these surgeries, it is not clear what the best position of the electrode belt on the patient’s thorax is, considering the cranial shift of the diaphragm. We monitored 16 patients undergoing a laparoscopic surgery with capnoperitoneum using EIT with two independent electrode belts at different tomographic levels: in the standard position of the 4th–6th intercostal space, as recommended by the manufacturer, and in a more cranial position at the level of the axilla. Functional residual capacity (FRC) was measured, and a recruitment maneuver was performed at the end of the procedure by raising the positive end-expiratory pressure (PEEP) by 5 cmH2O. The results based on the spectral analysis of the EIT signal show that the ventilation-related impedance changes are not detectable by the belt in the standard position. In general, the cranial belt position might be more suitable for the lung monitoring during the capnoperitoneum since the ventilation signal remains dominant in the obtained impedance waveform. FRC was significantly decreased by the capnoperitoneum and remained lower also after desufflation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 272 01 Kladno, Czech Republic.
- Department of Anesthesiology, Resuscitation and Intensive Care Medicine First Faculty of Medicine, The Military University Hospital Prague, Charles University, 121 08 Prague, Czech Republic.
- Clinic of Anesthesiology, Critical Care 1st Faculty of Medicine, Thomayer University Hospital Prague, Charles University, 140 59 Prague, Czech Republic.
ORCID-Profile: Kristyna Koldova, Martin Muller, Karel Roubik
Förderung
- Czech Technical University in Prague
Zitieren
APA
Koldova, K., Rara, A., Muller, M., Tyll, T., & Roubik, K. (2023). Cranial Electrode Belt Position Improves Diagnostic Possibilities of Electrical Impedance Tomography during Laparoscopic Surgery with Capnoperitoneum. Sensors. https://doi.org/10.3390/s23208644
Vancouver
Koldova K, Rara A, Muller M, Tyll T, Roubik K. Cranial Electrode Belt Position Improves Diagnostic Possibilities of Electrical Impedance Tomography during Laparoscopic Surgery with Capnoperitoneum. Sensors. 2023. doi:10.3390/s23208644
BibTeX
@article{Koldova2023,
author = {Koldova, Kristyna and Rara, Ales and Muller, Martin and Tyll, Tomas and Roubik, Karel},
title = {Cranial Electrode Belt Position Improves Diagnostic Possibilities of Electrical Impedance Tomography during Laparoscopic Surgery with Capnoperitoneum},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23208644}
}
EUVIMED