Stationary Explosive Trace Detection System Using Differential Ion Mobility Spectrometry (DMS)
Sensors · 19.10.2023 · 23 (20) · 8586
DOI: 10.3390/s23208586 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 19.10.2023. Verfasst von Monika Szyposzyńska und 4 weiteren Autor:innen. Beteiligte Einrichtung: Military Institute of Chemistry and Radiometry, al. gen. A. Chruściela "Montera" 105, 00-910 Warsaw, Poland. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Centre for Research and Development.
Themen: Mobilisation
Abstract (Originalsprache)
Detecting trace amounts of explosives is important for maintaining national security due to the growing threat of terror attacks. Particularly challenging is the increasing use of homemade explosives. Therefore, there is a constant need to improve existing technologies for detecting trace amounts of explosives. This paper describes the design of a stationary device (a gate) for detecting trace amounts of explosives and explosive taggants and the design of differential ion mobility spectrometers with a focus on the gas system. Nitromethane (NM), trimeric acetone peroxide (TATP), hexamine peroxide (HMTD), and explosive taggants 2,3-dimethyl-2,3-dinitrobutane (DMDNB) and 4-nitrotoluene (4NT) were used in this study. Gate measurements were carried out by taking air from the hands, pocket area, and shoes of the tested person. Two differential ion mobility spectrometers operating in two different modes were used as explosive detectors: a mode with a semi-permeable membrane to detect explosives with high vapor pressures (such as TATP) and a mode without a semi-permeable membrane (using direct introduction of the sample into the measuring chamber) to detect explosives with low vapor pressures (such as HMTD). The device was able to detect trace amounts of selected explosives/explosive taggants in 5 s.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Military Institute of Chemistry and Radiometry, al. gen. A. Chruściela "Montera" 105, 00-910 Warsaw, Poland.
- Military Institute of Armoured and Automotive Technology, Okuniewska 1, 05-070 Sulejówek, Poland.
ORCID-Profile: Monika Szyposzyńska
Förderung
- National Centre for Research and Development
Zitieren
APA
Szyposzyńska, M., Spławska, A., Ceremuga, M., Kot, P., & Maziejuk, M. (2023). Stationary Explosive Trace Detection System Using Differential Ion Mobility Spectrometry (DMS). Sensors, 23(20), 8586. https://doi.org/10.3390/s23208586
Vancouver
Szyposzyńska M, Spławska A, Ceremuga M, Kot P, Maziejuk M. Stationary Explosive Trace Detection System Using Differential Ion Mobility Spectrometry (DMS). Sensors. 2023;23(20):8586. doi:10.3390/s23208586
BibTeX
@article{Szyposzyska2023,
author = {Szyposzyńska, Monika and Spławska, Aleksandra and Ceremuga, Michał and Kot, Piotr and Maziejuk, Mirosław},
title = {Stationary Explosive Trace Detection System Using Differential Ion Mobility Spectrometry (DMS)},
journal = {Sensors},
year = {2023},
volume = {23},
number = {20},
pages = {8586},
doi = {10.3390/s23208586}
}
EUVIMED