Validating a Consumer Smartwatch for Nocturnal Respiratory Rate Measurements in Sleep Monitoring
Sensors · 2023
DOI: 10.3390/s23187976 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Hyunjun Jung und 3 weiteren Autor:innen. Beteiligte Einrichtung: Samsung Electronics, Suwon 16677, Republic of Korea. Hauptthemen laut MEDLINE: Respiratory Rate, Polysomnography, Sleep Apnea, Obstructive, Sleep. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Samsung Medical Center, Samsung Electronics.
Abstract (Originalsprache)
Wrist-based respiratory rate (RR) measurement during sleep faces accuracy limitations. This study aimed to assess the accuracy of the RR estimation function during sleep based on the severity of obstructive sleep apnea (OSA) using the Samsung Galaxy Watch (GW) series. These watches are equipped with accelerometers and photoplethysmography sensors for RR estimation. A total of 195 participants visiting our sleep clinic underwent overnight polysomnography while wearing the GW, and the RR estimated by the GW was compared with the reference RR obtained from the nasal thermocouple. For all participants, the root mean squared error (RMSE) of the average overnight RR and continuous RR measurements were 1.13 bpm and 1.62 bpm, respectively, showing a small bias of 0.39 bpm and 0.37 bpm, respectively. The Bland–Altman plots indicated good agreement in the RR measurements for the normal, mild, and moderate OSA groups. In participants with normal-to-moderate OSA, both average overnight RR and continuous RR measurements achieved accuracy rates exceeding 90%. However, for patients with severe OSA, these accuracy rates decreased to 79.45% and 75.8%, respectively. The study demonstrates the GW’s ability to accurately estimate RR during sleep, even though accuracy may be compromised in patients with severe OSA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Samsung Electronics, Suwon 16677, Republic of Korea.
- Department of Neurology, Ewha Womans University Seoul Hospital, Ewha Womans University College of Medicine, Seoul 07804, Republic of Korea.
- Departments of Neurology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea.
ORCID-Profile: Hyunjun Jung, Eun Yeon Joo
Förderung
- Samsung Medical Center
- Samsung Electronics
Zitieren
APA
Jung, H., Kim, D., Choi, J., & Joo, E. Y. (2023). Validating a Consumer Smartwatch for Nocturnal Respiratory Rate Measurements in Sleep Monitoring. Sensors. https://doi.org/10.3390/s23187976
Vancouver
Jung H, Kim D, Choi J, Joo EY. Validating a Consumer Smartwatch for Nocturnal Respiratory Rate Measurements in Sleep Monitoring. Sensors. 2023. doi:10.3390/s23187976
BibTeX
@article{Jung2023,
author = {Jung, Hyunjun and Kim, Dongyeop and Choi, Jongmin and Joo, Eun Yeon},
title = {Validating a Consumer Smartwatch for Nocturnal Respiratory Rate Measurements in Sleep Monitoring},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23187976}
}
EUVIMED