EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quantitative Comparison of Hand Kinematics Measured with a Markerless Commercial Head-Mounted Display and a Marker-Based Motion Capture System in Stroke Survivors

Antonino Casile iD, Giulia Fregna, Vittorio Boarini, Chiara Paoluzzi, Fabio Manfredini iD, Nicola Lamberti iD, Andrea Baroni iD, Sofia Straudi iD

Sensors · 15.09.2023 · 23 (18) · 7906

DOI: 10.3390/s23187906 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 15.09.2023. Verfasst von Antonino Casile und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, 98122 Messina, Italy. Hauptthemen laut MEDLINE: Stroke, Stroke Rehabilitation. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This work was supported by #NEXTGENERATIONEU (NGEU) and funded by the Ministry of University and Research (MUR), National Recovery and Resilience Plan (NRRP),…, Ministry of University and Research (MUR), National Recovery and Resilience Plan (NRRP).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Upper-limb paresis is common after stroke. An important tool to assess motor recovery is to use marker-based motion capture systems to measure the kinematic characteristics of patients’ movements in ecological scenarios. These systems are, however, very expensive and not readily available for many rehabilitation units. Here, we explored whether the markerless hand motion capabilities of the cost-effective Oculus Quest head-mounted display could be used to provide clinically meaningful measures. A total of 14 stroke patients executed ecologically relevant upper-limb tasks in an immersive virtual environment. During task execution, we recorded their hand movements simultaneously by means of the Oculus Quest’s and a marker-based motion capture system. Our results showed that the markerless estimates of the hand position and peak velocity provided by the Oculus Quest were in very close agreement with those provided by a marker-based commercial system with their regression line having a slope close to 1 (maximum distance: mean slope = 0.94 ± 0.1; peak velocity: mean slope = 1.06 ± 0.12). Furthermore, the Oculus Quest had virtually the same sensitivity as that of a commercial system in distinguishing healthy from pathological kinematic measures. The Oculus Quest was as accurate as a commercial marker-based system in measuring clinically meaningful upper-limb kinematic parameters in stroke patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StrokeStroke RehabilitationHumansMotion CaptureBiomechanical PhenomenaHandUpper ExtremityMovement

Stichwörter der Autor:innen

Oculus QuestOptitrackhead-mounted displaymarkerless motion capture systemmotion analysismotor recoverystroke

Autor:innen und Institutionen

  • Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, 98122 Messina, Italy.
  • Center of Translational Neurophysiology of Speech and Communication (CTNSC), Istituto Italiano di Tecnologia (IIT), 44121 Ferrara, Italy.
  • Doctoral Program in Translational Neurosciences and Neurotechnologies, University of Ferrara, 44121 Ferrara, Italy.
  • Department of Mathematics and Computer Science, University of Ferrara, 44121 Ferrara, Italy.
  • Department of Neuroscience and Rehabilitation, University of Ferrara, 44121 Ferrara, Italy.
  • Department of Neuroscience, Ferrara University Hospital, 44124 Ferrara, Italy.

ORCID-Profile: Antonino Casile, Fabio Manfredini, Nicola Lamberti, Andrea Baroni, Sofia Straudi

Förderung

  • This work was supported by #NEXTGENERATIONEU (NGEU) and funded by the Ministry of University and Research (MUR), National Recovery and Resilience Plan (NRRP),…
  • Ministry of University and Research (MUR), National Recovery and Resilience Plan (NRRP)

Zitieren

APA

Casile, A., Fregna, G., Boarini, V., Paoluzzi, C., Manfredini, F., Lamberti, N., Baroni, A., & Straudi, S. (2023). Quantitative Comparison of Hand Kinematics Measured with a Markerless Commercial Head-Mounted Display and a Marker-Based Motion Capture System in Stroke Survivors. Sensors, 23(18), 7906. https://doi.org/10.3390/s23187906

Vancouver

Casile A, Fregna G, Boarini V, Paoluzzi C, Manfredini F, Lamberti N, et al. Quantitative Comparison of Hand Kinematics Measured with a Markerless Commercial Head-Mounted Display and a Marker-Based Motion Capture System in Stroke Survivors. Sensors. 2023;23(18):7906. doi:10.3390/s23187906

BibTeX
@article{Casile2023,
  author = {Casile, Antonino and Fregna, Giulia and Boarini, Vittorio and Paoluzzi, Chiara and Manfredini, Fabio and Lamberti, Nicola and Baroni, Andrea and Straudi, Sofia},
  title = {Quantitative Comparison of Hand Kinematics Measured with a Markerless Commercial Head-Mounted Display and a Marker-Based Motion Capture System in Stroke Survivors},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {18},
  pages = {7906},
  doi = {10.3390/s23187906}
}
Kostenlos starten →