Utilizing Low-Cost Sensors to Monitor Indoor Air Quality in Mongolian Gers
Sensors · 2023
DOI: 10.3390/s23187721 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Callum E Flowerday und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA. Hauptthemen laut MEDLINE: Air Pollution, Indoor, Environmental Monitoring. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deseret International Charities and through a generous donation from Milt and Heidi Shipp, Deseret International Charities in Salt Lake City, Milt and Heidi Shipp.
Abstract (Originalsprache)
Air quality has important climate and health effects. There is a need, therefore, to monitor air quality both indoors and outdoors. Methods of measuring air quality should be cost-effective if they are to be used widely, and one such method is low-cost sensors (LCS). This study reports on the use of LCSs in Ulaanbataar, Mongolia to measure PM2.5 concentrations inside yurts or “gers”. Some of these gers were part of a non-government agency (NGO) initiative to improve insulating properties of these housing structures. The goal of the NGO was to decrease particulate emissions inside the gers; a secondary result was to lower the use of coal and other biomass material. LCSs were installed in gers heated primarily by coal, and interior air quality was measured. Gers that were modified by increasing their insulating capacities showed a 17.5% reduction in PM2.5 concentrations, but this is still higher than recommended by health organizations. Gers that were insulated and used a combination of both coal and electricity showed a 19.1% reduction in PM2.5 concentrations. Insulated gers that used electricity for both heating and cooking showed a 48% reduction in PM2.5 but still had higher concentrations of PM2.5 that were 6.4 times higher than recommended by the World Health Organization (WHO). Nighttime and daytime trends followed similar patterns and trends in PM2.5 concentrations with slight variations. It was found that at nighttime the outside PM2.5 concentrations were generally higher than the inside concentrations of the gers in this study, meaning that PM2.5 would flow into the ger whenever the doors were opened, causing spikes in PM2.5 concentrations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA.
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT 84602, USA.
- Department of Chemistry and Physics, Southeast Missouri State University, One University Plaza, Cape Girardeau, MO 63701, USA.
ORCID-Profile: Callum E Flowerday, Philip Lundrigan, Christopher Kitras, Tu Nguyen, Jaron C Hansen
Förderung
- Deseret International Charities and through a generous donation from Milt and Heidi Shipp
- Deseret International Charities in Salt Lake City
- Milt and Heidi Shipp
Zitieren
APA
Flowerday, C. E., Lundrigan, P., Kitras, C., Nguyen, T., & Hansen, J. C. (2023). Utilizing Low-Cost Sensors to Monitor Indoor Air Quality in Mongolian Gers. Sensors. https://doi.org/10.3390/s23187721
Vancouver
Flowerday CE, Lundrigan P, Kitras C, Nguyen T, Hansen JC. Utilizing Low-Cost Sensors to Monitor Indoor Air Quality in Mongolian Gers. Sensors. 2023. doi:10.3390/s23187721
BibTeX
@article{Flowerday2023,
author = {Flowerday, Callum E and Lundrigan, Philip and Kitras, Christopher and Nguyen, Tu and Hansen, Jaron C},
title = {Utilizing Low-Cost Sensors to Monitor Indoor Air Quality in Mongolian Gers},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23187721}
}
EUVIMED