Fachartikel in der Zeitschrift Sensors, online erschienen am 24.08.2023. Verfasst von Shuomang Shi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil, Construction, and Environmental Engineering, North Dakota State University, Fargo, ND 58105, USA. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation, U. S. Department of Transportation Pipeline and Hazardous Materials Safety Admin-istration (PHMSA), U. S. Department of Transportation Pipeline and Hazardous Materials Safety Administration (PHMSA).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Internal corrosion is a major concern in ensuring the safety of transmission and gathering pipelines in Structural Health Monitoring (SHM). It usually requires numerous sensors deployed inside the piping system to comprehensively cover the locations with high corrosion rates. This study presents a hybrid modeling strategy using Computational Fluid Dynamics (CFD) and Genetic Algorithm (GA) to improve the sensor placement scheme for corrosion detection and monitoring. The essence of the proposed strategy harnesses the well-validated physical modeling capability of the CFD to simulate the oil-water two-phase flow and the stochastic searching ability of the GA to explore better solutions on a global level. The CFD-based corrosion rate prediction was validated through experimental results and further used to form the initial population for GA optimization. Importantly, fitness was defined by considering both sensing effectiveness and cost of sensor coverage. The hybrid modeling strategy was implemented through case studies, where three typical pipe fittings were used to demonstrate the applicability of the sensor layout design for corrosion detection in pipelines. The GA optimization results show high accuracy for sensor placement inside the pipelines. The best fitness of the U-shaped, upward-inclined, and downward-inclined pipes were 0.9415, 0.9064, and 0.9183, respectively. Upon this, the hybrid modeling strategy can provide a promising tool for the pipeline industry to design the practical placement.

Schlagwörter

Stichwörter der Autor:innen

Computational Fluid Dynamics (CFD)Genetic Algorithm (GA)Structural Health Monitoring (SHM)corrosionpipelines

Autor:innen und Institutionen

  • Department of Civil, Construction, and Environmental Engineering, North Dakota State University, Fargo, ND 58105, USA.
  • Department of Civil and Environmental Engineering, School of Engineering, Rutgers, The State University of New Jersey, New Brunswick, NJ 08901, USA.
  • Department of Computer Science, North Dakota State University, Fargo, ND 58105, USA.

ORCID-Profile: Simone Ludwig, Hao Wang

Förderung

  • National Science Foundation
  • U. S. Department of Transportation Pipeline and Hazardous Materials Safety Admin-istration (PHMSA)
  • U. S. Department of Transportation Pipeline and Hazardous Materials Safety Administration (PHMSA)

Zitieren

APA

Shi, S., Jiang, B., Ludwig, S., Xu, L., Wang, H., Huang, Y., & Yan, F. (2023). Optimization for Pipeline Corrosion Sensor Placement in Oil-Water Two-Phase Flow Using CFD Simulations and Genetic Algorithm. Sensors, 23(17), 7379. https://doi.org/10.3390/s23177379

Vancouver

Shi S, Jiang B, Ludwig S, Xu L, Wang H, Huang Y, et al. Optimization for Pipeline Corrosion Sensor Placement in Oil-Water Two-Phase Flow Using CFD Simulations and Genetic Algorithm. Sensors. 2023;23(17):7379. doi:10.3390/s23177379

BibTeX
@article{Shi2023,
  author = {Shi, Shuomang and Jiang, Baiyu and Ludwig, Simone and Xu, Luyang and Wang, Hao and Huang, Ying and Yan, Fei},
  title = {Optimization for Pipeline Corrosion Sensor Placement in Oil-Water Two-Phase Flow Using CFD Simulations and Genetic Algorithm},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {17},
  pages = {7379},
  doi = {10.3390/s23177379}
}
Kostenlos starten →