Investigation of the Relationship between Body Parameters and mAs Using Non-Contact Two-Dimensional Thickness Measurement in Chest Digital Radiography

Jia-Ru Lin, I-Hao Cheng, Yu-Syuan Liang, Jyun-Jie Li, Jen-Ming Tsai, Min-Tsung Wang, Te-Pao Lin, Su-Lan Huang, Ming-Chung Chou iD

Sensors · 14.08.2023 · 23 (16) · 7169

DOI: 10.3390/s23167169 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 14.08.2023. Verfasst von Jia-Ru Lin und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Kaohsiung Armed Force General Hospital, Kaohsiung 802, Taiwan. Hauptthemen laut MEDLINE: Radiographic Image Enhancement, Thorax. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Kaohsiung Armed Forces General Hospital, Ministry of Science and Technology, Ministry of Science and Technology of Taiwan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The current study aimed to investigate the relationship between body parameters and the current–time product (mAs) in chest digital radiography using a non-contact infrared thickness-measurement sensor. An anthropomorphic chest phantom was first used to understand variations in mAs over multiple positionings during chest radiography when using the automatic exposure control (AEC) technique. In a human study, 929 consecutive male subjects who underwent regular chest examinations were enrolled, and their height (H), weight (W), and body mass index (BMI) were recorded. In addition, their chest thickness (T) was measured at exhalation using a non-contact infrared sensor, and chest radiography was then performed using the AEC technique. Finally, the relationship between four body parameters (T, BMI, T*BMI, and W/H) and mAs was investigated by fitting the body parameters to mAs using three curve models. The phantom study showed that the maximum mAs was 1.76 times higher than the lowest mAs during multiple positionings in chest radiography. In the human study, all chest radiographs passed the routine quality control procedure and had an exposure index between 100 and 212. In curve fitting, the comparisons showed that W/H had a closer relationship with mAs than the other body parameters, while the first-order power model with W/H fitted to mAs performed the best and had an R-square of 0.9971. We concluded that the relationship between W/H and mAs in the first-order power model may be helpful in predicting the optimal mAs and reducing the radiation dose for chest radiography when using the AEC technique.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiographic Image EnhancementThoraxMaleHumansRadiographyBody Mass IndexExhalation

Stichwörter der Autor:innen

automatic exposure controlbody parameterschest radiographymAsnon-contact infrared sensor

Autor:innen und Institutionen

  • Department of Radiology, Kaohsiung Armed Force General Hospital, Kaohsiung 802, Taiwan.
  • Department of Radiation Oncology, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 833, Taiwan.
  • Department of Medical Imaging and Radiological Sciences, Kaohsiung Medical University, Kaohsiung 807, Taiwan.
  • Department of Medical Research, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan.
  • Center for Big Data Research, Kaohsiung Medical University, Kaohsiung 807, Taiwan.

ORCID-Profile: Ming-Chung Chou

Förderung

  • Kaohsiung Armed Forces General Hospital
  • Ministry of Science and Technology
  • Ministry of Science and Technology of Taiwan

Zitieren

APA

Lin, J. R., Cheng, I. H., Liang, Y. S., Li, J. J., Tsai, J. M., Wang, M. T., Lin, T. P., Huang, S. L., & Chou, M. C. (2023). Investigation of the Relationship between Body Parameters and mAs Using Non-Contact Two-Dimensional Thickness Measurement in Chest Digital Radiography. Sensors, 23(16), 7169. https://doi.org/10.3390/s23167169

Vancouver

Lin JR, Cheng IH, Liang YS, Li JJ, Tsai JM, Wang MT, et al. Investigation of the Relationship between Body Parameters and mAs Using Non-Contact Two-Dimensional Thickness Measurement in Chest Digital Radiography. Sensors. 2023;23(16):7169. doi:10.3390/s23167169

BibTeX
@article{Lin2023,
  author = {Lin, Jia-Ru and Cheng, I-Hao and Liang, Yu-Syuan and Li, Jyun-Jie and Tsai, Jen-Ming and Wang, Min-Tsung and Lin, Te-Pao and Huang, Su-Lan and Chou, Ming-Chung},
  title = {Investigation of the Relationship between Body Parameters and mAs Using Non-Contact Two-Dimensional Thickness Measurement in Chest Digital Radiography},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {16},
  pages = {7169},
  doi = {10.3390/s23167169}
}