Wearable and Noninvasive Device for Integral Congestive Heart Failure Management in the IoMT Paradigm

José L Ausín iD, Javier Ramos iD, Antonio Lorido, Pedro Molina, J Francisco Duque-Carrillo iD

Sensors · 2023

DOI: 10.3390/s23167055 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von José L Ausín und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical, Electronics and Control Engineering, University of Extremadura, 06006 Badajoz, Spain. Hauptthemen laut MEDLINE: Heart Failure, Heart Diseases, Wearable Electronic Devices. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerio de Ciencia e Innovación, Government of Extremadura, Junta de Extremadura (Spain).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Noninvasive remote monitoring of hemodynamic variables is essential in optimizing treatment opportunities and predicting rehospitalization in patients with congestive heart failure. The objective of this study is to develop a wearable bioimpedance-based device, which can provide continuous measurement of cardiac output and stroke volume, as well as other physiological parameters for a greater prognosis and prevention of congestive heart failure. The bioimpedance system, which is based on a robust and cost-effective measuring principle, was implemented in a CMOS application specific integrated circuit, and operates as the analog front-end of the device, which has been provided with a radio-frequency section for wireless communication. The operating parameters of the proposed wearable device are remotely configured through a graphical user interface to measure the magnitude and the phase of complex impedances over a bandwidth of 1 kHz to 1 MHz. As a result of this study, a cardiac activity monitor was implemented, and its accuracy was evaluated in 33 patients with different heart diseases, ages, and genders. The proposed device was compared with a well-established technique such as Doppler echocardiography, and the results showed that the two instruments are clinically equivalent.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart FailureHeart DiseasesWearable Electronic DevicesMaleHumansFemaleHeartCardiac Output

Stichwörter der Autor:innen

CMOS integrated circuitsbioimpedancecardiac output assessmentcongestive heart failure

Autor:innen und Institutionen

  • Department of Electrical, Electronics and Control Engineering, University of Extremadura, 06006 Badajoz, Spain.
  • BioBee Technologies S.L., Extremadura Science and Technology Park, 06006 Badajoz, Spain.

ORCID-Profile: José L Ausín, Javier Ramos, J Francisco Duque-Carrillo

Förderung

  • Ministerio de Ciencia e Innovación
  • Government of Extremadura
  • Junta de Extremadura (Spain)

Zitieren

APA

Ausín, J. L., Ramos, J., Lorido, A., Molina, P., & Duque-Carrillo, J. F. (2023). Wearable and Noninvasive Device for Integral Congestive Heart Failure Management in the IoMT Paradigm. Sensors. https://doi.org/10.3390/s23167055

Vancouver

Ausín JL, Ramos J, Lorido A, Molina P, Duque-Carrillo JF. Wearable and Noninvasive Device for Integral Congestive Heart Failure Management in the IoMT Paradigm. Sensors. 2023. doi:10.3390/s23167055

BibTeX
@article{Ausn2023,
  author = {Ausín, José L and Ramos, Javier and Lorido, Antonio and Molina, Pedro and Duque-Carrillo, J Francisco},
  title = {Wearable and Noninvasive Device for Integral Congestive Heart Failure Management in the IoMT Paradigm},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23167055}
}