EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An Investigation of Surface EMG Shorts-Derived Training Load during Treadmill Running

Kurtis Ashcroft, Tony Robinson iD, Joan Condell iD, Victoria Penpraze, Andrew White, Stephen P Bird iD

Sensors · 2023

DOI: 10.3390/s23156998 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Kurtis Ashcroft und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Computing, Engineering and the Built Environment, Ulster University, Derry BT48 7JL, UK. Hauptthemen laut MEDLINE: Exercise Test, Running. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The purpose of this study was two-fold: (1) to determine the sensitivity of the sEMG shorts-derived training load (sEMG-TL) during different running speeds; and (2) to investigate the relationship between the oxygen consumption, heart rate (HR), rating of perceived exertion (RPE), accelerometry-based PlayerLoadTM (PL), and sEMG-TL during a running maximum oxygen uptake (V˙O2max) test. The study investigated ten healthy participants. On day one, participants performed a three-speed treadmill test at 8, 10, and 12 km·h−1 for 2 min at each speed. On day two, participants performed a V˙O2max test. Analysis of variance found significant differences in sEMG-TL at all three speeds (p < 0.05). A significantly weak positive relationship between sEMG-TL and %V˙O2max (r = 0.31, p < 0.05) was established, while significantly strong relationships for 8 out of 10 participants at the individual level (r = 0.72–0.97, p < 0.05) were found. Meanwhile, the accelerometry PL was not significantly related to %V˙O2max (p > 0.05) and only demonstrated significant correlations in 3 out of 10 participants at the individual level. Therefore, the sEMG shorts-derived training load was sensitive in detecting a work rate difference of at least 2 km·h−1. sEMG-TL may be an acceptable metric for the measurement of internal loads and could potentially be used as a surrogate for oxygen consumption.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Exercise TestRunningHumansPhysical ExertionOxygen ConsumptionOxygenHeart Rate

Stichwörter der Autor:innen

compression shortsexternal loadinternal loadoxygen consumptionsurface electromyographytextile sEMGtraining load

Substanzen

Oxygen

Autor:innen und Institutionen

  • Faculty of Computing, Engineering and the Built Environment, Ulster University, Derry BT48 7JL, UK.
  • School of Cardiovascular and Metabolic Health, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow G12 8QQ, UK.
  • School of Health and Medical Sciences, University of Southern Queensland, Ipswich, QLD 4305, Australia.

ORCID-Profile: Tony Robinson, Joan Condell, Stephen P Bird

Zitieren

APA

Ashcroft, K., Robinson, T., Condell, J., Penpraze, V., White, A., & Bird, S. P. (2023). An Investigation of Surface EMG Shorts-Derived Training Load during Treadmill Running. Sensors. https://doi.org/10.3390/s23156998

Vancouver

Ashcroft K, Robinson T, Condell J, Penpraze V, White A, Bird SP. An Investigation of Surface EMG Shorts-Derived Training Load during Treadmill Running. Sensors. 2023. doi:10.3390/s23156998

BibTeX
@article{Ashcroft2023,
  author = {Ashcroft, Kurtis and Robinson, Tony and Condell, Joan and Penpraze, Victoria and White, Andrew and Bird, Stephen P},
  title = {An Investigation of Surface EMG Shorts-Derived Training Load during Treadmill Running},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23156998}
}
Kostenlos starten →