EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Estimated Nucleotide Reconstruction Quality Symbols of Basecalling Tools for Oxford Nanopore Sequencing

Wiktor Kuśmirek iD

Sensors · 2023

DOI: 10.3390/s23156787 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Wiktor Kuśmirek. Beteiligte Einrichtung: Institute of Computer Science, Warsaw University of Technology, 00-661 Warsaw, Poland. Hauptthemen laut MEDLINE: Nanopore Sequencing, Nanopores. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Center, POB Research Centre Cybersecurity and Data Science of Warsaw University of Technology, Polish National Science Center.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Currently, one of the fastest-growing DNA sequencing technologies is nanopore sequencing. One of the key stages involved in processing sequencer data is the basecalling process, where the input sequence of currents measured on the nanopores of the sequencer reproduces the DNA sequences, called DNA reads. Many of the applications dedicated to basecalling, together with the DNA sequence, provide the estimated quality of the reconstruction of a given nucleotide (quality symbols are contained on every fourth line of the FASTQ file; each nucleotide in the FASTQ file corresponds to exactly one estimated nucleotide reconstruction quality symbol). Herein, we compare the estimated nucleotide reconstruction quality symbols (signs from every fourth line of the FASTQ file) reported by other basecallers. The conducted experiments consisted of basecalling the same raw datasets from the nanopore device by other basecallers and comparing the provided quality symbols, denoting the estimated quality of the nucleotide reconstruction. The results show that the estimated quality reported by different basecallers may vary, depending on the tool used, particularly in terms of range and distribution. Moreover, we mapped basecalled DNA reads to reference genomes and calculated matched and mismatched rates for groups of nucleotides with the same quality symbol. Finally, the presented paper shows that the estimated nucleotide reconstruction quality reported in the basecalling process is not used in any investigated tool for processing nanopore DNA reads.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nanopore SequencingNanoporesNucleotidesSequence Analysis, DNADNAHigh-Throughput Nucleotide Sequencing

Stichwörter der Autor:innen

FASTQbasecallingbioinformaticsnanoporequality evaluation

Substanzen

NucleotidesDNA

Autor:innen und Institutionen

  • Institute of Computer Science, Warsaw University of Technology, 00-661 Warsaw, Poland.

ORCID-Profile: Wiktor Kuśmirek

Förderung

  • National Science Center
  • POB Research Centre Cybersecurity and Data Science of Warsaw University of Technology
  • Polish National Science Center

Zitieren

APA

Kuśmirek, W. (2023). Estimated Nucleotide Reconstruction Quality Symbols of Basecalling Tools for Oxford Nanopore Sequencing. Sensors. https://doi.org/10.3390/s23156787

Vancouver

Kuśmirek W. Estimated Nucleotide Reconstruction Quality Symbols of Basecalling Tools for Oxford Nanopore Sequencing. Sensors. 2023. doi:10.3390/s23156787

BibTeX
@article{Kumirek2023,
  author = {Kuśmirek, Wiktor},
  title = {Estimated Nucleotide Reconstruction Quality Symbols of Basecalling Tools for Oxford Nanopore Sequencing},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23156787}
}
Kostenlos starten →