Frugal Heart Rate Correction Method for Scalable Health and Safety Monitoring in Construction Sites
Sensors · 17.07.2023 · 23 (14) · 6464
DOI: 10.3390/s23146464 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 17.07.2023. Verfasst von Piotr Sowiński und 9 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Mathematics and Information Science, Warsaw University of Technology, ul. Koszykowa 75, 00-662 Warsaw, Poland. Hauptthemen laut MEDLINE: Workplace, Electrocardiography. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission, Centre for Priority Research Area Artificial Intelligence and Robotics of Warsaw University of Technology within the Excellence Initiative: Research University….
Abstract (Originalsprache)
Continuous, real-time monitoring of occupational health and safety in high-risk workplaces such as construction sites can substantially improve the safety of workers. However, introducing such systems in practice is associated with a number of challenges, such as scaling up the solution while keeping its cost low. In this context, this work investigates the use of an off-the-shelf, low-cost smartwatch to detect health issues based on heart rate monitoring in a privacy-preserving manner. To improve the smartwatch’s low measurement quality, a novel, frugal machine learning method is proposed that corrects measurement errors, along with a new dataset for this task. This method’s integration with the smartwatch and the remaining parts of the health and safety monitoring system (built on the ASSIST-IoT reference architecture) are presented. This method was evaluated in a laboratory environment in terms of its accuracy, computational requirements, and frugality. With an experimentally established mean absolute error of 8.19 BPM, only 880 bytes of required memory, and a negligible impact on the performance of the device, this method meets all relevant requirements and is expected to be field-tested in the coming months. To support reproducibility and to encourage alternative approaches, the dataset, the trained model, and its implementation on the smartwatch were published under free licenses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Mathematics and Information Science, Warsaw University of Technology, ul. Koszykowa 75, 00-662 Warsaw, Poland.
- Systems Research Institute, Polish Academy of Sciences, ul. Newelska 6, 01-447 Warsaw, Poland.
- Department of Personal Protective Equipment, Central Institute for Labour Protection-National Research Institute, ul. Wierzbowa 48, 90-133 Lodz, Poland.
- Department of Complex Systems, Faculty of Electrical and Computer Engineering, Rzeszow University of Technology, al. Powstańców Warszawy 12, 35-959 Rzeszów, Poland.
ORCID-Profile: Piotr Sowiński, Kajetan Rachwał, Anastasiya Danilenka, Karolina Bogacka, Monika Kobus, Anna Dąbrowska, Andrzej Paszkiewicz, Marek Bolanowski, Maria Ganzha, Marcin Paprzycki
Förderung
- European Commission
- Centre for Priority Research Area Artificial Intelligence and Robotics of Warsaw University of Technology within the Excellence Initiative: Research University…
Zitieren
APA
Sowiński, P., Rachwał, K., Danilenka, A., Bogacka, K., Kobus, M., Dąbrowska, A., Paszkiewicz, A., Bolanowski, M., Ganzha, M., & Paprzycki, M. (2023). Frugal Heart Rate Correction Method for Scalable Health and Safety Monitoring in Construction Sites. Sensors, 23(14), 6464. https://doi.org/10.3390/s23146464
Vancouver
Sowiński P, Rachwał K, Danilenka A, Bogacka K, Kobus M, Dąbrowska A, et al. Frugal Heart Rate Correction Method for Scalable Health and Safety Monitoring in Construction Sites. Sensors. 2023;23(14):6464. doi:10.3390/s23146464
BibTeX
@article{Sowiski2023,
author = {Sowiński, Piotr and Rachwał, Kajetan and Danilenka, Anastasiya and Bogacka, Karolina and Kobus, Monika and Dąbrowska, Anna and Paszkiewicz, Andrzej and Bolanowski, Marek and Ganzha, Maria and Paprzycki, Marcin},
title = {Frugal Heart Rate Correction Method for Scalable Health and Safety Monitoring in Construction Sites},
journal = {Sensors},
year = {2023},
volume = {23},
number = {14},
pages = {6464},
doi = {10.3390/s23146464}
}
EUVIMED