Fault Detection in Power Distribution Networks Based on Comprehensive-YOLOv5
Sensors · 14.07.2023 · 23 (14) · 6410
DOI: 10.3390/s23146410 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 14.07.2023. Verfasst von Shengsuo Niu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, China. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: STATE GRID INFO & TELECOM GROUP, STATE GRID INFO & TELECOM GROUP.
Abstract (Originalsprache)
Real-time fault detection in power distribution networks has become a popular issue in current power systems. However, the low power and computational capabilities of edge devices often fail to meet the requirements of real-time detection. To overcome these challenges, this paper proposes a lightweight algorithm, named Comprehensive-YOLOv5, for identifying defects in distribution networks. The proposed method focuses on achieving rapid localization and accurate identification of three common defects: insulator without loop, cable detachment from the insulator, and cable detachment from the spacer. Based on the You Only Look Once version 5 (YOLOv5) algorithm, this paper adopts GhostNet to reconstruct the original backbone of YOLOv5; introduces Bidirectional Feature Pyramid Network (BiFPN) structure to replace Path Aggregation Network (PANet) for feature fusion, which enhances the feature fusion ability; and replaces Generalized Intersection over Union GIOU with Focal Extended Intersection over Union (Focal-EIOU) to optimize the loss function, which improves the mean average precision and speed of the algorithm. The effectiveness of the improved Comprehensive-YOLOv5 algorithm is verified through a “morphological experiment”, while an “algorithm comparison experiment” confirms its superiority over other algorithms. Compared with the original YOLOv5, the Comprehensive-YOLOv5 algorithm improves mean average precision (mAP) from 88.3% to 90.1% and increases Frames per second (FPS) from 20 to 52 frames. This improvement significantly reduces false positives and false negatives in defect detection. Consequently, the proposed algorithm enhances detection speed and improves inspection efficiency, providing a viable solution for real-time detection and deployment at the edge of power distribution networks.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, China.
Förderung
- STATE GRID INFO & TELECOM GROUP
- STATE GRID INFO & TELECOM GROUP
Zitieren
APA
Niu, S., Zhou, X., Zhou, D., Yang, Z., Liang, H., & Su, H. (2023). Fault Detection in Power Distribution Networks Based on Comprehensive-YOLOv5. Sensors, 23(14), 6410. https://doi.org/10.3390/s23146410
Vancouver
Niu S, Zhou X, Zhou D, Yang Z, Liang H, Su H. Fault Detection in Power Distribution Networks Based on Comprehensive-YOLOv5. Sensors. 2023;23(14):6410. doi:10.3390/s23146410
BibTeX
@article{Niu2023,
author = {Niu, Shengsuo and Zhou, Xiaosen and Zhou, Dasen and Yang, Zhiyao and Liang, Haiping and Su, Haifeng},
title = {Fault Detection in Power Distribution Networks Based on Comprehensive-YOLOv5},
journal = {Sensors},
year = {2023},
volume = {23},
number = {14},
pages = {6410},
doi = {10.3390/s23146410}
}
EUVIMED