In-Water Fish Body-Length Measurement System Based on Stereo Vision
Sensors · 12.07.2023 · 23 (14) · 6325
DOI: 10.3390/s23146325 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 12.07.2023. Verfasst von Minggang Zhou und 3 weiteren Autor:innen. Beteiligte Einrichtung: Agricultural Machinery Engineering Research and Design Institute, Hubei University of Technology, Wuhan 430068, China. Hauptthemen laut MEDLINE: Water, Vision, Binocular. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hubei Key R&D Programs, Hubei Provincial Key R&D Program.
Abstract (Originalsprache)
Fish body length is an essential monitoring parameter in aquaculture engineering. However, traditional manual measurement methods have been found to be inefficient and harmful to fish. To overcome these shortcomings, this paper proposes a non-contact measurement method that utilizes binocular stereo vision to accurately measure the body length of fish underwater. Binocular cameras capture RGB and depth images to acquire the RGB-D data of the fish, and then the RGB images are selectively segmented using the contrast-adaptive Grab Cut algorithm. To determine the state of the fish, a skeleton extraction algorithm is employed to handle fish with curved bodies. The errors caused by the refraction of water are then analyzed and corrected. Finally, the best measurement points from the RGB image are extracted and converted into 3D spatial coordinates to calculate the length of the fish, for which measurement software was developed. The experimental results indicate that the mean relative percentage error for fish-length measurement is 0.9%. This paper presents a method that meets the accuracy requirements for measurement in aquaculture while also being convenient for implementation and application.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Agricultural Machinery Engineering Research and Design Institute, Hubei University of Technology, Wuhan 430068, China.
Förderung
- Hubei Key R&D Programs
- Hubei Provincial Key R&D Program
Zitieren
APA
Zhou, M., Shen, P., Zhu, H., & Shen, Y. (2023). In-Water Fish Body-Length Measurement System Based on Stereo Vision. Sensors, 23(14), 6325. https://doi.org/10.3390/s23146325
Vancouver
Zhou M, Shen P, Zhu H, Shen Y. In-Water Fish Body-Length Measurement System Based on Stereo Vision. Sensors. 2023;23(14):6325. doi:10.3390/s23146325
BibTeX
@article{Zhou2023,
author = {Zhou, Minggang and Shen, Pingfeng and Zhu, Hao and Shen, Yang},
title = {In-Water Fish Body-Length Measurement System Based on Stereo Vision},
journal = {Sensors},
year = {2023},
volume = {23},
number = {14},
pages = {6325},
doi = {10.3390/s23146325}
}
EUVIMED