Effects of Gas and Steam Humidity on Particulate Matter Measurements Obtained Using Light-Scattering Sensors
Sensors · 06.07.2023 · 23 (13) · 6199
DOI: 10.3390/s23136199 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 06.07.2023. Verfasst von Hyunsik Kim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil Engineering, Korea National University of Transportation, Chungju 27469, Republic of Korea. Hauptthemen laut MEDLINE: Particulate Matter, Air Pollutants. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education.
Abstract (Originalsprache)
With the increasing need for particulate matter (PM) monitoring, the demand for light-scattering sensors that allow for real-time measurements of PM is increasing. This light-scattering method involves irradiating light to the aerosols in the atmosphere to analyze the scattered light and measure mass concentrations. Humidity affects the measurement results. The humidity in an outdoor environment may exist as gas or steam, such as fog. While the impact of humidity on the light-scattering measurement remains unclear, an accurate estimation of ambient PM concentration is a practical challenge. Therefore, this study investigated the effects of humidity on light-scattering measurements by analyzing the variation in the PM concentration measured by the sensor when relative humidity was due to gaseous and steam vapor. The gaseous humidity did not cause errors in the PM measurements via the light-scattering method. In contrast, steam humidity, such as that caused by fog, resulted in errors in the PM measurement. The results help determine the factors to be considered before applying a light-scattering sensor in an outdoor environment. Based on these factors, directions for technological development can be presented regarding the correction of measurement errors induced by vapor in outdoor environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Civil Engineering, Korea National University of Transportation, Chungju 27469, Republic of Korea.
- School of Architecture, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea.
ORCID-Profile: Hyunsik Kim, Jeonghwan Kim, Seungjun Roh
Förderung
- National Research Foundation of Korea
- Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education
Zitieren
APA
Kim, H., Kim, J., & Roh, S. (2023). Effects of Gas and Steam Humidity on Particulate Matter Measurements Obtained Using Light-Scattering Sensors. Sensors, 23(13), 6199. https://doi.org/10.3390/s23136199
Vancouver
Kim H, Kim J, Roh S. Effects of Gas and Steam Humidity on Particulate Matter Measurements Obtained Using Light-Scattering Sensors. Sensors. 2023;23(13):6199. doi:10.3390/s23136199
BibTeX
@article{Kim2023,
author = {Kim, Hyunsik and Kim, Jeonghwan and Roh, Seungjun},
title = {Effects of Gas and Steam Humidity on Particulate Matter Measurements Obtained Using Light-Scattering Sensors},
journal = {Sensors},
year = {2023},
volume = {23},
number = {13},
pages = {6199},
doi = {10.3390/s23136199}
}