EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Temperature Dependence of the Thermo-Optic Coefficient of SiO2 Glass

Gaspar Rego iD

Sensors · 29.06.2023 · 23 (13) · 6023

DOI: 10.3390/s23136023 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 29.06.2023. Verfasst von Gaspar Rego. Beteiligte Einrichtung: ADiT-LAB, Instituto Politécnico de Viana do Castelo, Rua Escola Industrial e Comercial Nun'Álvares, 4900-347 Viana do Castelo, Portugal. Hauptthemen laut MEDLINE: Quartz, Silicon Dioxide. Die Arbeit wurde bisher 95-mal zitiert (Crossref) und nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e Tecnologia, FCT-Fundação para a Ciência e a Tecnologia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents a thorough analysis on the temperature dependence of the thermo-optic coefficient, dn/dT, of four bulk annealed pure-silica glass samples (type I—natural quartz: Infrasil 301; type II—quartz crystal powder: Heraeus Homosil; type III—synthetic vitreous silica: Corning 7980 and Suprasil 3001) from room temperature down to 0 K. The three/four term temperature dependent Sellmeier equations and respective coefficients were considered, which results from fitting to the raw data obtained by Leviton et al. The thermo-optic coefficient was extrapolated down to zero Kelvin. We have obtained dn/dT values ranging from 8.16 × 10−6 up to 8.53 × 10−6 for the four samples at 293 K and for a wavelength of 1.55 μm. For the Corning 7980 SiO2 glass, the thermo-optic coefficient decreases monotonically, from 8.74 × 10−6 down to 8.16 × 10−6, from the visible range up to the third telecommunication window, being almost constant above 1.3 μm. The Ghosh’s model was revisited, and it was concluded that the thermal expansion coefficient only accounts for about 2% of the thermo-optic coefficient, and we have obtained an expression for the temperature behavior of the silica excitonic bandgap. Wemple’s model was also analyzed where we have also considered the material dispersion in order to determine the coefficients and respective temperature dependences. The limitations of this model were also discussed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

QuartzSilicon DioxideTemperatureEyeGlass

Stichwörter der Autor:innen

cryogenic temperaturesmaterial dispersionrefractive indexsilica glassthermo-optic coefficient

Substanzen

QuartzSilicon Dioxide

Autor:innen und Institutionen

  • ADiT-LAB, Instituto Politécnico de Viana do Castelo, Rua Escola Industrial e Comercial Nun'Álvares, 4900-347 Viana do Castelo, Portugal.
  • Center for Applied Photonics, INESC TEC, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal.

ORCID-Profile: Gaspar Rego

Förderung

  • Fundação para a Ciência e Tecnologia
  • FCT-Fundação para a Ciência e a Tecnologia

Zitieren

APA

Rego, G. (2023). Temperature Dependence of the Thermo-Optic Coefficient of SiO2 Glass. Sensors, 23(13), 6023. https://doi.org/10.3390/s23136023

Vancouver

Rego G. Temperature Dependence of the Thermo-Optic Coefficient of SiO2 Glass. Sensors. 2023;23(13):6023. doi:10.3390/s23136023

BibTeX
@article{Rego2023,
  author = {Rego, Gaspar},
  title = {Temperature Dependence of the Thermo-Optic Coefficient of SiO2 Glass},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {13},
  pages = {6023},
  doi = {10.3390/s23136023}
}
Kostenlos starten →